Home > Products > Liquid Solution > Oil Filter
Products

Liquid Solution

Our liquid filtration solutions utilize state-of-the-art filter media to capture even the smallest particles and debris. Whether you're handling water, chemicals, oil, or other liquids, our filtration systems are versatile and adaptable to meet your specific requirements.
Didn't find your industry solution? Consult our technical experts immediately.

Production Workshop

Modern Production Equipment

Our equipment is built to last, utilizing durable materials and reliable components to ensure long-term performance with minimal downtime. Our production equipment is easy to maintain and user-friendly, designed for maximum convenience and productivity.

Complete production process

The production workshop is fully equipped with the most advanced machines and technology from cutting, welding, spraying to assembly and testing.

Why Choose Us?

Xinxiang City Huahang Filter Co., Ltd is professional in the production of Hydraulic Filter, Air Filter and Pipe Filter.Product series range from Oil Filter, Air Filter, Water Filter, Polymer Filter,Candle Filter Element, Stainless Steel Filter to filter Coalescer and Separator. Product structure has tubular type, platy type, fold type, wraping type, sliding pillar type, frame type, cabas type, tank type and disc type, etc..

Tailored Customization for Operational Excellence

ISO-Certified Quality with End-to-End Testing

Scalable Production & Technological Innovation

Global After-Sales Support & Compliance Assurance

Our production equipment

Our equipment and product display

Our equipment and product display

Our equipment and product display

Our equipment and product display

Our equipment and product display

Our equipment and product display

Our equipment and product display

Our equipment and product display

Application

Application

Application

Application

Filters are essential for maintaining the efficiency, performance, and lifespan of machinery across various industries. By removing impurities and contaminants from liquids and gases, they help reduce maintenance costs, increase productivity, and ensure safe equipment operation. Whether in automotive, manufacturing, oil and gas, or residential environments, filters are indispensable components that play a vital role in modern engineering and technology.

Related Cases

Xinxiang City Huahang Filter Co., Ltd is professional in the production of Hydraulic Filter, Air Filter and Pipe Filter.Product series range from Oil Filter, Air Filter, Water Filter, Polymer Filter,Candle Filter Element, Stainless Steel Filter to filter Coalescer and Separator.

FAQ

How do I cross-reference my existing OEM part number to a Huahang element?

Send the OEM number plus one physical measurement. A part number alone is not enough to ship against.


* What we match on — Outside diameter, inside diameter, overall height, media grade, micron rating, end-cap and seal layout, bypass setting, collapse rating and flow direction.


* When the number is ambiguous — Superseded numbers, numbers shared across several machine builds, or an element that has clearly been substituted before. In those cases a photo of the housing nameplate and a caliper reading of the old element settle it.


* Why we insist — The most common return is not a wrong size. It is an element that fits the bore but seals on the wrong face.

What collapse or burst pressure can your elements take, and how does flow direction affect it?

Collapse rating comes from the core, not the media — and it only holds in service if two conditions are met.


* Typical ranges — A light return-line element with a perforated core around 10–25 bar; a pressure-line element with a heavy spiral core 100 bar and above; high-collapse designs higher still.


* Condition 1 — flow direction — Return elements are normally outside-in. Run one backwards and the pleat pack goes into tension, folds, and bypasses.


* Condition 2 — bypass setting — The housing’s bypass valve must crack below the element’s collapse rating. Otherwise a cold start or a neglected change-out crushes the element before the valve ever opens.

Can your elements handle fire-resistant fluids such as phosphate ester and EHC systems?

Yes, but the build changes, and this is exactly where a generic replacement fails.


* Seals — Move to FKM or PTFE. NBR swells and softens in phosphate ester.


* Media and bonds — Binder, pleat-seam adhesive and end-cap adhesive all have to resist ester attack; some phenolic resin systems do not.


* Water-based fluids (HFA, HFC) — A different problem again — free water, biological growth, and media that must not delaminate when wet.


* Expect a different ΔP — These fluids run at higher viscosity and lower lubricity than mineral oil, so the same element reads differently on the gauge.

What is the difference between an oil separator element and an oil mist separator?

Same job at different pressures: one works inside a compressor separator tank, the other on a breather or vacuum pump.


* Oil separator element — Removes oil aerosol from compressed air and returns the collected oil to the sump. Rated in mg/m³ carryover, typically a few mg/m³ for a healthy element.


* Oil mist separator — Comparable duty at near-atmospheric pressure, but sized on flow and oil type rather than on pressure.


* Saturation signals, common to both — Carryover climbing, oil consumption rising with no visible leak, ΔP trending up, and an element that comes out dark and varnished instead of evenly coated.

Sintered mesh, sintered powder or pleated stainless steel — how do I choose between them?

Choose on duty, not on price. The three constructions also fail in different ways.


* Sintered mesh : 2 to 5 diffusion-bonded wire layers — High strength, genuinely backflushable, cleanable surface, absolute ratings typically 3–100 µm. Best for catalyst recovery, amine and water service, and anything cleaned in place.


* Sintered powder : A true depth filter: narrow pore distribution, finer ratings (0.5–1 µm with titanium), more dirt capacity per unit area, better resistance to compressive load. The default for polymer melt, high-pressure gas and food or pharmaceutical duty where no fibre release is allowed.


* Pleated stainless : Woven wire cloth in a pleat pack — large area and low ΔP at high flow for coarse duty, and the lowest cost per square metre of area.

How do you ensure the quality and performance of the filter element?

Quality is our lifeline. We insist on:


Strict material selection: Use high-quality raw materials that meet industry standards.


Advanced technology: Use automated or precision-controlled production processes.


Multiple quality inspections: Implement full-process quality inspections from raw material storage to finished product delivery (including size, sealing, filtration efficiency, integrity testing, etc.).


Performance testing: Key products will undergo actual working condition simulation testing.


Compliance with standards: Our production and products comply with [e.g.: ISO 9001].


Customized verification: For customized filter elements, we will confirm key performance indicators with customers and provide test reports (if necessary).

Can metal cartridges be cleaned and reused, and how many cycles should I expect?

Yes . Reusability is usually the whole economic case, and it comes with two hard rules.


* Methods — Reverse-flow backflush at 1.5–2× service rate, ultrasonic cleaning in mild alkaline detergent, caustic or acid CIP, and calcination or steam for carbon and polymer residues.


* Never brush or scrape — That smears the pore structure and drives contamination deeper instead of out.


* Stay inside the chloride limit — 304 will pit at the weld in chloride-bearing water long before the media fails.


* Track the clean ΔP — Once it sits 30–50% above the original baseline, the pore structure is degrading rather than fouling — the cartridge is finished.

What is the difference between nominal and absolute micron ratings on metal media?

The two words are not interchangeable, and the gap between them is where process upsets come from.


- Nominal — Means 90–95% of particles above the stated size are retained, usually with no defined test method behind the claim.


- Absolute — Means 99.9% or better, verified by a defined method — bubble point to ISO 4003, glass-bead challenge, or a recognised particulate challenge.


- Ask which method — Metal ratings are normally derived from bubble-point pore size, so the method is the number.


- Why it matters — A mesh sold as 10 µm nominal will comfortably pass 25 µm particles. Irrelevant for a coarse strainer; fatal upstream of a spin pack or a membrane.

How do I specify a metal cartridge for polymer melt filtration?

Two numbers decide whether the cartridge survives: start-up ΔP, and collapse rating against the screen changer’s maximum.


* Process data — Polymer type (PET, PP, PA6, PE), melt temperature, viscosity at that temperature, throughput in kg/h, allowable pressure build-up.


* Hardware — Screen changer, spin pack or candle housing, with its pressure rating.


* Design on start-up, not steady state — Cold polymer can produce five to ten times the service differential pressure.


* No fibre release — Sintered powder or sintered mesh, not woven cloth, downstream of an extruder.

What do you need for a custom end connection, thread or flange?

Flange standards cause more rework than any other single item on a custom order.


* Dimensions : OD, ID, overall length, thread or flange specification and bolt circle. A drawing, or a photo with a caliper in frame, is enough.


* Connection and seal : M30×1, M36×2, BSP or NPT thread, ANSI or DIN flange, quick connector, bayonet — plus seal type and material.


* Duty : Media and rating, flow, allowable ΔP, temperature, pressure, quantity.

Which filter media should I use for my dust — polyester, anti-static, fiberglass, paper or non-woven?

Match the media to the dust chemistry and to how the collector cleans. Price is the last criterion.


- Polyester needle felt — to about 130 °C — General dry dust. The default choice, and the right starting point for most collectors.


- PTFE-laminated polyester — to about 130 °C — Fine or sticky fume, where dust must not key into the depth of the felt.


- Anti-static polyester, carbon or stainless fibre — to about 130 °C — Combustible dust, and any stream where charge build-up makes the cartridge hold dust it should have released.


- Fiberglass — to about 250 °C — High temperature, and any duty requiring H13 or H14 efficiency.


- Paper or cellulose — Coarse pre-filtration where cost dominates.


- Non-woven synthetic blends — Abrasive or moisture-laden streams.

Does a higher pleat count always mean better performance?

More pleats means more area — until the pleats crowd and cleaning can no longer reach the pleat root.


* What you gain — Lower face velocity, and therefore lower differential pressure at a given flow.


* What you lose — The gaps close under load, the cartridge blinds from the inside out, and the extra area is wasted.


* The metric that matters — Pleat pitch against dust loading: fine sticky dust wants wide spacing, free-flowing granular dust tolerates tight packing.


* Also check — Pleat depth against cage inside diameter. Deep pleats in a small cartridge fold over and create a dead zone that never cleans.

Why do my cartridges fail before their rated life, and how can I extend it?

Four modes account for most premature change-outs, and the fixes sit upstream of the cartridge.


* Media burst or abrasion — High inlet velocity, a missing deflector, or pulse pressure over about 6 bar at the venturi.


* Cage collapse — Differential pressure above rating, or water ingress.


* Adhesive or gasket failure — Temperature past the glue’s limit, or solvent attack.


* Rust-through — Galvanised cages in condensing streams.

What is the difference between a coalescer filter and a separator filter?

They are two distinct technologies often used together to remove liquids from a gas or liquid stream. The key difference is their core function:

* A Coalescer Filter merges tiny, invisible liquid droplets into large, heavy ones.

* A Separator Filter catches and drains those large droplets from the flow.

How They Work:

* Coalescer: The stream passes through a special media (like fine fibers). Microscopic aerosol droplets collide and merge (coalesce) into drops large enough to drain. It solves the problem of suspended mist.

* Separator: The flow then enters a chamber with baffles or vanes. The now-large droplets hit the surfaces, fall out by gravity, and collect in a sump. It provides the final, clean separation.

When do I need fiberglass or stainless instead of polyester, and how do I handle sparks?

Above roughly 130 °C continuous, polyester is out — and the gasket and cage need checking at the same time.

* Next step up — Fiberglass holds to about 260 °C; stainless or ceramic options go further.

* The weak link changes — Often the media survives and the glue line fails first, so the temperature rating must cover the whole assembly.

* Sparks — Welding, grinding, biomass boilers, foundry: a spark arrestor or pre-settling chamber upstream is mandatory. Fiberglass resists heat, not molten metal impingement.

* Condensing streams — Acid dew point corrodes cages faster than it destroys media, and a rusted cage collapses into the fan.

Hot topics:

Q1. Where should filtration sit in a hydraulic circuit — suction, pressure, return or off-line?

A1: Different positions do different jobs, and the common mistake is asking one element to do all of them.

  • Suction — A coarse strainer (around 100–125 µm wire mesh) that protects the pump from catastrophic ingress. It must stay coarse — anything finer strangles the pump inlet and causes cavitation.
  • Pressure line — Protects the most sensitive components downstream, typically servo and proportional valves. Tightest media rating, highest collapse rating.
  • Return line — Catches wear debris generated inside the system before it reaches the reservoir. The workhorse position, and where most replacement elements live.
  • Off-line / kidney loop — An independent circulation circuit, and the best polishing position because flow and ΔP are decoupled from the machine’s duty cycle.

 

Q2: When do I need a stainless steel oil filter element instead of fiberglass or paper?

A2: Choose stainless when the fluid, the temperature, or the cleanliness requirement rules out organic media.

  • Aggressive or water-containing fluids — Phosphate ester with free water, emulsions, hot glycol — organic media and their resin binders degrade in exactly these fluids.
  • High temperature — Beyond roughly 135 °C continuous, cellulose is finished and even fiberglass resin systems become marginal.
  • No fibre migration allowed — Woven or sintered stainless gives a metal-only flow path for food-grade, pharmaceutical or nuclear duty.
  • Washable duty — A stainless element can be ultrasonically cleaned and reinstalled many times, which suits mobile and remote equipment where spares are far away.

 

Q3: My elements keep failing early — how do I diagnose what actually killed them?

A3: Everything looks the same in the bin, but each failure mode points at a different root cause.

  • Collapsed or distorted pleats — Bypass set above the collapse rating, a cold-start viscosity spike, or a flow surge.
  • Pleats bunched at the seam — Wrong flow direction, or a missing inner support.
  • Heavy sludge or varnish — Oil oxidation or water ingress — a new element will load again within weeks unless the oil itself is dealt with.
  • Fibres found downstream — Damaged media, or a single-layer element where a graded multilayer was specified.
  • Fine metallic glitter in the pleats — A wearing pump or motor announcing itself.

 

Q4: Can metal cartridges be cleaned and reused, and how many cycles should I expect?

A4: Yes. Reusability is usually the whole economic case, and it comes with two hard rules.

  • Methods — Reverse-flow backflush at 1.5–2× service rate, ultrasonic cleaning in mild alkaline detergent, caustic or acid CIP, and calcination or steam for carbon and polymer residues.
  • Never brush or scrape — That smears the pore structure and drives contamination deeper instead of out.
  • Stay inside the chloride limit — 304 will pit at the weld in chloride-bearing water long before the media fails.
  • Track the clean ΔP — Once it sits 30–50% above the original baseline, the pore structure is degrading rather than fouling — the cartridge is finished.

 

Q5: When is titanium powder sintered worth the extra cost over 316L?

A5: Titanium earns its premium in three situations, and is wasted in a fourth.

  • Chloride or hypochlorite service — Where 316L pits and 904L is only marginal.
  • High temperature with thermal cycling — A stable oxide layer and lower expansion coefficient keep the bond intact.
  • When the corrosion product is the contaminant — Catalyst recovery, brine, seawater injection, hot nitric acid — the filter has to be chemically invisible as well as fine.
  • A practical bonus — About 40% lighter, which genuinely matters when one person handles a 40-inch element on a top-loading housing.