Home > Products > Liquid Solution > Alternative Oil Filter Element > HYDAC Filter > 0330R020PHC-KB Replace Hydac Oil Filter

0330R020PHC-KB Replace Hydac Oil Filter

Product type
Replace Hydraulic Oil Filter Element
Part number
0330R020PHC-KB
Filter layer
Paper
End caps
Nylon
Filtration rate
1~50μm
Working temperature
-20~+110℃
Sealing material
NBR
Package
Neutral carton package
Share:
Products Description
Specification
Features

Products Description

The 0330R020PHC-KB Replace Hydac Oil Filter is engineered as a direct, high-performance alternative to the original Hydac filter element, delivering consistent contamination control for return line applications.

This direct replacement element utilizes advanced filtration media to effectively capture and retain fine wear particles, dirt, and sludge. By maintaining optimal oil cleanliness, it directly supports consistent hydraulic performance, reduces long-term maintenance costs, and protects your valuable machinery investment in demanding industrial environments.

Specifications

Type Replace Hydraulic Oil Filter Element
Part number 0330R020PHC-KB
Filter layer Paper
Working pressure 16 ~160 bar
Filtration rate 1~50 μm
Working temperature -20~+110℃
Sealing material NBR
Package Neutral carton package

This is the standard specification of the replace Hydac oil filter element. Send your inquiry here and get the quotation within 12 hours.

Features

Direct Replacement: Precisely engineered to match the form, fit, and function of the original part number, ensuring perfect compatibility and reliable performance.
High-Efficiency Contaminant Removal: Features quality depth filtration media designed for effective capture and retention of fine particulate, maintaining the required fluid cleanliness to protect sensitive hydraulic components.
Durable Industrial Construction: Built with robust materials and a strong support core to ensure structural integrity and consistent performance under typical system operating pressures.
Essential System Protection: Helps prevent abrasive wear on critical components, contributing to sustained system efficiency, reduced frequency of repairs, and maximized equipment availability.
Didn't find your industry solution? Consult our technical experts immediately.

Compatible Model List

There are part of the models we can provide. If you don’t find the models you need, please contact us to get the details.

0110R0100N 0750 R 010 BN 4 HC 0950 R 005 BN 3HC 1300 R 050 W ON 0500 R 005 BN 3 HC
1300R050WON 2700 R 005 ON/PO /-V 0240 R 005 ON/PO /-V-KB 0660 R 010 ON/PO /-V 0950 R 010 ON/PO /-V-KB
2700R020G/HC/-KB-SFREE 2700 R 005 ON/PO /-KB 0240 R 010 ON/PO 0660 R 010 ON/PO /-KB 0950 R 020 ON/PO
2700R005ON/PO/-KB 2700 R 005 ON/PO /-V-KB 0240 R 010 ON/PO /-V 0660 R 010 ON/PO /-V-KB 0950 R 020 ON/PO /-V
2700R005ON/-SFREE-KB 2700 R 010 ON/PO 0240 R 010 ON/PO /-KB 0660 R 020 ON/PO 0950 R 020 ON/PO /-KB
2700R010ON 2700 R 010 ON/PO /-V 0240 R 010 ON/PO /-V-KB 0660 R 020 ON/PO /-V 0950 R 020 ON/PO /-V-KB
2700R010ON/SFREE 2700 R 010 ON/PO /-KB 0240 R 020 ON/PO 0660 R 020 ON/PO /-KB 1300 R 005 ON/PO
2700R010ON/PO  1299906 2700 R 010 ON/PO /-V-KB 0240 R 020 ON/PO /-V 0660 R 020 ON/PO /-V-KB 1300 R 005 ON/PO /-V
2700R010ON/PO/-KB   1314451 2700 R 020 ON/PO 0240 R 020 ON/PO /-KB 0850 R 005 ON/PO 1300 R 005 ON/PO /-KB
2700R010ON/PO/-KB/SS 2700 R 020 ON/PO /-V 0240 R 020 ON/PO /-V-KB 0850 R 005 ON/PO /-V 1300 R 005 ON/PO /-V-KB
2700R010ON/PO/-V 2700 R 020 ON/PO /-KB 0330 R 005 ON/PO 0850 R 005 ON/PO /-KB 1300 R 010 ON/PO
2700R010ON/-SFREE 2700 R 020 ON/PO /-V-KB 0330 R 005 ON/PO /-V 0850 R 005 ON/PO /-V-KB 1300 R 010 ON/PO /-V
2700R010ON/-SFREE-KB 0110 R 005 ON/PO 0330 R 005 ON/PO /-KB 0850 R 010 ON/PO 1300 R 010 ON/PO /-KB
2700R020ON/PO   1299351 0110 R 005 ON/PO /-V 0330 R 005 ON/PO /-V-KB 0850 R 010 ON/PO /-V 1300 R 010 ON/PO /-V-KB

Manufacturer & Supplier

Huahang Filter is dedicated to creating replacement parts that match the stringent specifications of original equipment. Our modern manufacturing base and ISO-certified processes ensure that every component delivers reliable performance and guaranteed compatibility, meeting the needs of industries across more than 120 countries.

Core Manufacturing and Quality Strengths

  • Precision Fit & Seamless Integration: We meticulously replicate all critical dimensions, sealing interfaces, and performance characteristics to ensure a perfect, leak-free installation in your HYDAC filter housing, guaranteeing optimal system integrity from the first use.
  • Verified Performance Through Rigorous Control: Our vertically integrated production and strict quality management ensure each element offers consistent high-efficiency particle capture, excellent dirt-holding capacity, and the structural strength to withstand system pressure cycles.
  • Global Supply Chain Assurance: With the majority of our products exported internationally, we have built a resilient supply network. This ensures dependable availability and timely delivery of critical replacement parts to support your operations anywhere.
  • Application-Focused Engineering: Our technical expertise allows us to understand specific application challenges, ensuring our replacement filters are built to provide effective protection under real-world operating conditions.

Custom Service

At Huahang Filter, we offer robust customization services to tailor the filter element to your specific needs.

  • Custom Filtration Ratings: Available in various micron ratings from 1μm to 100μm

  • Custom Seal Materials: NBR, Viton, EPDM, or PTFE-encapsulated options

  • Custom End Caps: Alternative materials or configurations to fit unique housings

  • Custom Collapse Pressure: Reinforced construction for higher pressure requirements

  • Custom Packaging: Bulk packaging or individual boxes with branding

Contact Huahang Filter today to discuss your filter element requirements and request a quote!

FAQ

Q: What does the model number 0330R020PHC-KB mean?

A: The model number follows Hydac’s naming convention:

  • 0330 – Filter size (dimensions matching the housing)

  • R – Return line element

  • 020 – 20 micron filtration rating

  • P/HC – Paper filter media (Hydac standard)

  • KB – No bypass valve

Q: Is this a direct replacement for the original Hydac filter?

A: Yes. This element is manufactured as a form, fit, and function replacement for the original Hydac 0330R020PHC-KB. It matches the exact dimensions, seal configuration, and performance characteristics to ensure a drop-in replacement without modifications.

Q: Is this element suitable for high-pressure applications?

A: This element is specifically designed for return line applications, where operating pressures are typically lower than in pressure lines. Return line elements like the 0330R series should not be used in high-pressure line applications. For pressure line applications, Hydac’s “D” series elements are the appropriate choice.

Related Products

Related Cases

Xinxiang City Huahang Filter Co., Ltd is professional in the production of Hydraulic Filter, Air Filter and Pipe Filter.Product series range from Oil Filter, Air Filter, Water Filter, Polymer Filter,Candle Filter Element, Stainless Steel Filter to filter Coalescer and Separator.

FAQ

How do I cross-reference my existing OEM part number to a Huahang element?

Send the OEM number plus one physical measurement. A part number alone is not enough to ship against.


* What we match on — Outside diameter, inside diameter, overall height, media grade, micron rating, end-cap and seal layout, bypass setting, collapse rating and flow direction.


* When the number is ambiguous — Superseded numbers, numbers shared across several machine builds, or an element that has clearly been substituted before. In those cases a photo of the housing nameplate and a caliper reading of the old element settle it.


* Why we insist — The most common return is not a wrong size. It is an element that fits the bore but seals on the wrong face.

What collapse or burst pressure can your elements take, and how does flow direction affect it?

Collapse rating comes from the core, not the media — and it only holds in service if two conditions are met.


* Typical ranges — A light return-line element with a perforated core around 10–25 bar; a pressure-line element with a heavy spiral core 100 bar and above; high-collapse designs higher still.


* Condition 1 — flow direction — Return elements are normally outside-in. Run one backwards and the pleat pack goes into tension, folds, and bypasses.


* Condition 2 — bypass setting — The housing’s bypass valve must crack below the element’s collapse rating. Otherwise a cold start or a neglected change-out crushes the element before the valve ever opens.

Can your elements handle fire-resistant fluids such as phosphate ester and EHC systems?

Yes, but the build changes, and this is exactly where a generic replacement fails.


* Seals — Move to FKM or PTFE. NBR swells and softens in phosphate ester.


* Media and bonds — Binder, pleat-seam adhesive and end-cap adhesive all have to resist ester attack; some phenolic resin systems do not.


* Water-based fluids (HFA, HFC) — A different problem again — free water, biological growth, and media that must not delaminate when wet.


* Expect a different ΔP — These fluids run at higher viscosity and lower lubricity than mineral oil, so the same element reads differently on the gauge.

What is the difference between an oil separator element and an oil mist separator?

Same job at different pressures: one works inside a compressor separator tank, the other on a breather or vacuum pump.


* Oil separator element — Removes oil aerosol from compressed air and returns the collected oil to the sump. Rated in mg/m³ carryover, typically a few mg/m³ for a healthy element.


* Oil mist separator — Comparable duty at near-atmospheric pressure, but sized on flow and oil type rather than on pressure.


* Saturation signals, common to both — Carryover climbing, oil consumption rising with no visible leak, ΔP trending up, and an element that comes out dark and varnished instead of evenly coated.

Sintered mesh, sintered powder or pleated stainless steel — how do I choose between them?

Choose on duty, not on price. The three constructions also fail in different ways.


* Sintered mesh : 2 to 5 diffusion-bonded wire layers — High strength, genuinely backflushable, cleanable surface, absolute ratings typically 3–100 µm. Best for catalyst recovery, amine and water service, and anything cleaned in place.


* Sintered powder : A true depth filter: narrow pore distribution, finer ratings (0.5–1 µm with titanium), more dirt capacity per unit area, better resistance to compressive load. The default for polymer melt, high-pressure gas and food or pharmaceutical duty where no fibre release is allowed.


* Pleated stainless : Woven wire cloth in a pleat pack — large area and low ΔP at high flow for coarse duty, and the lowest cost per square metre of area.

How do you ensure the quality and performance of the filter element?

Quality is our lifeline. We insist on:


Strict material selection: Use high-quality raw materials that meet industry standards.


Advanced technology: Use automated or precision-controlled production processes.


Multiple quality inspections: Implement full-process quality inspections from raw material storage to finished product delivery (including size, sealing, filtration efficiency, integrity testing, etc.).


Performance testing: Key products will undergo actual working condition simulation testing.


Compliance with standards: Our production and products comply with [e.g.: ISO 9001].


Customized verification: For customized filter elements, we will confirm key performance indicators with customers and provide test reports (if necessary).

Can metal cartridges be cleaned and reused, and how many cycles should I expect?

Yes . Reusability is usually the whole economic case, and it comes with two hard rules.


* Methods — Reverse-flow backflush at 1.5–2× service rate, ultrasonic cleaning in mild alkaline detergent, caustic or acid CIP, and calcination or steam for carbon and polymer residues.


* Never brush or scrape — That smears the pore structure and drives contamination deeper instead of out.


* Stay inside the chloride limit — 304 will pit at the weld in chloride-bearing water long before the media fails.


* Track the clean ΔP — Once it sits 30–50% above the original baseline, the pore structure is degrading rather than fouling — the cartridge is finished.

What is the difference between nominal and absolute micron ratings on metal media?

The two words are not interchangeable, and the gap between them is where process upsets come from.


- Nominal — Means 90–95% of particles above the stated size are retained, usually with no defined test method behind the claim.


- Absolute — Means 99.9% or better, verified by a defined method — bubble point to ISO 4003, glass-bead challenge, or a recognised particulate challenge.


- Ask which method — Metal ratings are normally derived from bubble-point pore size, so the method is the number.


- Why it matters — A mesh sold as 10 µm nominal will comfortably pass 25 µm particles. Irrelevant for a coarse strainer; fatal upstream of a spin pack or a membrane.

How do I specify a metal cartridge for polymer melt filtration?

Two numbers decide whether the cartridge survives: start-up ΔP, and collapse rating against the screen changer’s maximum.


* Process data — Polymer type (PET, PP, PA6, PE), melt temperature, viscosity at that temperature, throughput in kg/h, allowable pressure build-up.


* Hardware — Screen changer, spin pack or candle housing, with its pressure rating.


* Design on start-up, not steady state — Cold polymer can produce five to ten times the service differential pressure.


* No fibre release — Sintered powder or sintered mesh, not woven cloth, downstream of an extruder.

What do you need for a custom end connection, thread or flange?

Flange standards cause more rework than any other single item on a custom order.


* Dimensions : OD, ID, overall length, thread or flange specification and bolt circle. A drawing, or a photo with a caliper in frame, is enough.


* Connection and seal : M30×1, M36×2, BSP or NPT thread, ANSI or DIN flange, quick connector, bayonet — plus seal type and material.


* Duty : Media and rating, flow, allowable ΔP, temperature, pressure, quantity.

Which filter media should I use for my dust — polyester, anti-static, fiberglass, paper or non-woven?

Match the media to the dust chemistry and to how the collector cleans. Price is the last criterion.


- Polyester needle felt — to about 130 °C — General dry dust. The default choice, and the right starting point for most collectors.


- PTFE-laminated polyester — to about 130 °C — Fine or sticky fume, where dust must not key into the depth of the felt.


- Anti-static polyester, carbon or stainless fibre — to about 130 °C — Combustible dust, and any stream where charge build-up makes the cartridge hold dust it should have released.


- Fiberglass — to about 250 °C — High temperature, and any duty requiring H13 or H14 efficiency.


- Paper or cellulose — Coarse pre-filtration where cost dominates.


- Non-woven synthetic blends — Abrasive or moisture-laden streams.

Does a higher pleat count always mean better performance?

More pleats means more area — until the pleats crowd and cleaning can no longer reach the pleat root.


* What you gain — Lower face velocity, and therefore lower differential pressure at a given flow.


* What you lose — The gaps close under load, the cartridge blinds from the inside out, and the extra area is wasted.


* The metric that matters — Pleat pitch against dust loading: fine sticky dust wants wide spacing, free-flowing granular dust tolerates tight packing.


* Also check — Pleat depth against cage inside diameter. Deep pleats in a small cartridge fold over and create a dead zone that never cleans.

Why do my cartridges fail before their rated life, and how can I extend it?

Four modes account for most premature change-outs, and the fixes sit upstream of the cartridge.


* Media burst or abrasion — High inlet velocity, a missing deflector, or pulse pressure over about 6 bar at the venturi.


* Cage collapse — Differential pressure above rating, or water ingress.


* Adhesive or gasket failure — Temperature past the glue’s limit, or solvent attack.


* Rust-through — Galvanised cages in condensing streams.

What is the difference between a coalescer filter and a separator filter?

They are two distinct technologies often used together to remove liquids from a gas or liquid stream. The key difference is their core function:

* A Coalescer Filter merges tiny, invisible liquid droplets into large, heavy ones.

* A Separator Filter catches and drains those large droplets from the flow.

How They Work:

* Coalescer: The stream passes through a special media (like fine fibers). Microscopic aerosol droplets collide and merge (coalesce) into drops large enough to drain. It solves the problem of suspended mist.

* Separator: The flow then enters a chamber with baffles or vanes. The now-large droplets hit the surfaces, fall out by gravity, and collect in a sump. It provides the final, clean separation.

When do I need fiberglass or stainless instead of polyester, and how do I handle sparks?

Above roughly 130 °C continuous, polyester is out — and the gasket and cage need checking at the same time.

* Next step up — Fiberglass holds to about 260 °C; stainless or ceramic options go further.

* The weak link changes — Often the media survives and the glue line fails first, so the temperature rating must cover the whole assembly.

* Sparks — Welding, grinding, biomass boilers, foundry: a spark arrestor or pre-settling chamber upstream is mandatory. Fiberglass resists heat, not molten metal impingement.

* Condensing streams — Acid dew point corrodes cages faster than it destroys media, and a rusted cage collapses into the fan.
373-5471699
info@huahangfilter.com
+86 16690927259