Home > Products > Metal Cartridge > Sintered Filter > Metal Powder Sinter Filter > 5μm Stainless Steel Sintered Powder Filter 40×300

5μm Stainless Steel Sintered Powder Filter 40×300

Outer diameter
40 mm
Height
300 mm
Working temperature
-20~+100℃
Filter layer
Stainless steel
Filtration rating
5 μm
Connection
G¾ External thread
Origin
Henan,China
Brand
Huahang Filter
Share:
Products Description
Specification
Features

Products Description

The 5μm Stainless Steel Sintered Powder Filter is a precision-engineered all-metal filtration component manufactured from high-purity stainless steel powder through an advanced powder metallurgy process. With an outer diameter of 40 mm and a length of 300 mm, this filter element is widely used in industrial filtration applications requiring moderate flow capacity with compact footprint.

Unlike conventional filter media that rely on surface straining, this sintered powder filter is a three-dimensional porous structure created by thermally bonding stainless steel powder particles without fully melting them. The resulting interconnected pore network provides depth filtration capability, capturing contaminants throughout the entire thickness of the filter material rather than only on its surface. This monolithic construction contains no binders, no adhesives, and no shedding fibers—ensuring zero particle release into the filtrate.

Specifications

Below is the specification of the custom sintered filter. If you are interested in this kind of filters, please contact us to get more details.

Outer diameter 40 mm
Height 300 mm
Working temperature -20~+100℃
Filter layer Stainless steel
Filtration rate 5 μm
Connection G¾ External thread
Origin Henan, China
Brand Huahang Filter

 

Features

Fully Cleanable and Reusable: Supports multiple cleaning methods including backflushing, ultrasonic cleaning, chemical soaking, and high-temperature regeneration, dramatically reducing long-term operating costs
Superior Depth Filtration via Powder Sintering: The sintered metal powder matrix offers exceptional dirt-holding capacity and consistent filtration performance. Unlike surface filters, it traps particles throughout its depth, extending service intervals and providing stable, low pressure drop.
Excellent Thermal & Chemical Resistance: Constructed entirely from 304 or 316L stainless steel, the unit withstands high temperatures (suitable for most industrial process conditions) and resists corrosion from a wide range of aggressive chemicals, solvents, and process fluids.
High Structural Integrity & Cleanability: The monolithic sintered element is extremely strong, resistant to shock and pressure cycling. It can be effectively cleaned via back-flushing, ultrasonic methods, or thermal processing for repeated use, offering a long service life and low total cost of ownership.
Didn't find your industry solution? Consult our technical experts immediately.

Application areas

This sintered filter is suitable for precision filtration in the following industries:

  • Analytical and laboratory equipment: Protecting high-performance liquid chromatography systems, mass spectrometers, and precision sensors from particulate contamination.
  • Pharmaceutical and biotechnology: Sterile venting of bioreactors, filtration of buffers, solvents, and process gases in API production.
  • Microelectronics and chemical industry: Point-of-use filtration of high-purity process chemicals, photoresists, and specialty gases.
  • Fuel and hydraulic systems: Protecting precision control valves and metering devices in critical fluid power systems.

Manufacturer & Supplier of Sintered Filter

This sintered filter is manufactured by Huahang Filter, leveraging expertise in powder sintering technology and metallurgy. We focus on producing reliable, application-specific metal filters. Our controlled sintering process ensures consistent pore structure and performance in every batch. We provide technical support for material selection and can offer custom versions of this platform element with different end fittings, lengths, or surface treatments to meet unique system integration needs.

  • Controlled Sintering for Consistent Porosity: Our sintering process is finely tuned to create a uniform porous matrix, providing a reliable and predictable absolute filtration rating (e.g., 2, 5, 10, 20, 40 microns) in this small form factor.

  • Precision Thread Machining: The G¾ threads are machined to exacting standards, ensuring a perfect seal with standard fittings and preventing cross-threading or leakage in critical fluid paths.

  • High Material Purity & Integrity: We use high-grade 304 or 316L stainless steel powder, resulting in a filter with excellent corrosion resistance and structural integrity suitable for demanding analytical or process applications.

  • Durability and Cleanability: Despite its small size, the monolithic sintered structure is robust and can be backflushed or ultrasonically cleaned numerous times, offering long-term service life and value.

Contact us for more details about these metal sintered filters.

FAQ

Q1: What is the porosity of these filters?
A: Standard porosity ranges from 30-50% , providing an excellent balance of strength and flow. High-porosity versions up to 65% are available for applications requiring maximum flow with lower pressure drop .

Q2: Can stainless steel sintered powder filters be cleaned and reused?
A: Yes. One of the primary advantages of sintered powder filters is their reusability. They can be cleaned using:

  • Backflushing/Backpulsing: Reverse flow to dislodge captured particles
  • Ultrasonic cleaning: Thorough removal of embedded contaminants
  • Chemical cleaning: Soaking in compatible acids or solvents
  • High-temperature regeneration: Burning off organic contaminants

With proper cleaning, these elements can achieve extended service life and significantly reduce long-term operating costs.

Q3: What end connection types are available for this sintered filter element?
A: We offer multiple connection options to fit most filter housings:

  • Standard cartridge fittings: 222 O-ring, 226 O-ring [8†L10-L11]
  • Double Open End (DOE): With or without gaskets [8†L10-L11]
  • Threaded connections: NPT, BSP, Metric
  • Flanged connections: Various flange standards
  • Sanitary fittings: Tri-clamp for pharmaceutical and food applications
  • Custom connections: Designed to your specifications

Q4: How do I order the correct stainless steel sintered powder filter element?

A: To place an order or request a quotation, please provide:

  • Dimensions – According to your specific needs

  • Filtration rating –According to your specific needs

  • Connection type – 222 O‑ring, 226 O‑ring, M20 thread, M30 thread, flat/DOE, DN15 flange, DN20 flange, or custom design (provide details)

  • Flow direction – Inside‑out or outside‑in (specify per your housing design)

  • Operating conditions – Fluid type, temperature range, pressure range, pH range, and any special exposure concerns

  • Quantity – Sample order (1–5 pieces) or production volume (specify quantity)

Related Products

Related Cases

Xinxiang City Huahang Filter Co., Ltd is professional in the production of Hydraulic Filter, Air Filter and Pipe Filter.Product series range from Oil Filter, Air Filter, Water Filter, Polymer Filter,Candle Filter Element, Stainless Steel Filter to filter Coalescer and Separator.

FAQ

How do I cross-reference my existing OEM part number to a Huahang element?

Send the OEM number plus one physical measurement. A part number alone is not enough to ship against.


* What we match on — Outside diameter, inside diameter, overall height, media grade, micron rating, end-cap and seal layout, bypass setting, collapse rating and flow direction.


* When the number is ambiguous — Superseded numbers, numbers shared across several machine builds, or an element that has clearly been substituted before. In those cases a photo of the housing nameplate and a caliper reading of the old element settle it.


* Why we insist — The most common return is not a wrong size. It is an element that fits the bore but seals on the wrong face.

What collapse or burst pressure can your elements take, and how does flow direction affect it?

Collapse rating comes from the core, not the media — and it only holds in service if two conditions are met.


* Typical ranges — A light return-line element with a perforated core around 10–25 bar; a pressure-line element with a heavy spiral core 100 bar and above; high-collapse designs higher still.


* Condition 1 — flow direction — Return elements are normally outside-in. Run one backwards and the pleat pack goes into tension, folds, and bypasses.


* Condition 2 — bypass setting — The housing’s bypass valve must crack below the element’s collapse rating. Otherwise a cold start or a neglected change-out crushes the element before the valve ever opens.

Can your elements handle fire-resistant fluids such as phosphate ester and EHC systems?

Yes, but the build changes, and this is exactly where a generic replacement fails.


* Seals — Move to FKM or PTFE. NBR swells and softens in phosphate ester.


* Media and bonds — Binder, pleat-seam adhesive and end-cap adhesive all have to resist ester attack; some phenolic resin systems do not.


* Water-based fluids (HFA, HFC) — A different problem again — free water, biological growth, and media that must not delaminate when wet.


* Expect a different ΔP — These fluids run at higher viscosity and lower lubricity than mineral oil, so the same element reads differently on the gauge.

What is the difference between an oil separator element and an oil mist separator?

Same job at different pressures: one works inside a compressor separator tank, the other on a breather or vacuum pump.


* Oil separator element — Removes oil aerosol from compressed air and returns the collected oil to the sump. Rated in mg/m³ carryover, typically a few mg/m³ for a healthy element.


* Oil mist separator — Comparable duty at near-atmospheric pressure, but sized on flow and oil type rather than on pressure.


* Saturation signals, common to both — Carryover climbing, oil consumption rising with no visible leak, ΔP trending up, and an element that comes out dark and varnished instead of evenly coated.

Sintered mesh, sintered powder or pleated stainless steel — how do I choose between them?

Choose on duty, not on price. The three constructions also fail in different ways.


* Sintered mesh : 2 to 5 diffusion-bonded wire layers — High strength, genuinely backflushable, cleanable surface, absolute ratings typically 3–100 µm. Best for catalyst recovery, amine and water service, and anything cleaned in place.


* Sintered powder : A true depth filter: narrow pore distribution, finer ratings (0.5–1 µm with titanium), more dirt capacity per unit area, better resistance to compressive load. The default for polymer melt, high-pressure gas and food or pharmaceutical duty where no fibre release is allowed.


* Pleated stainless : Woven wire cloth in a pleat pack — large area and low ΔP at high flow for coarse duty, and the lowest cost per square metre of area.

How do you ensure the quality and performance of the filter element?

Quality is our lifeline. We insist on:


Strict material selection: Use high-quality raw materials that meet industry standards.


Advanced technology: Use automated or precision-controlled production processes.


Multiple quality inspections: Implement full-process quality inspections from raw material storage to finished product delivery (including size, sealing, filtration efficiency, integrity testing, etc.).


Performance testing: Key products will undergo actual working condition simulation testing.


Compliance with standards: Our production and products comply with [e.g.: ISO 9001].


Customized verification: For customized filter elements, we will confirm key performance indicators with customers and provide test reports (if necessary).

Can metal cartridges be cleaned and reused, and how many cycles should I expect?

Yes . Reusability is usually the whole economic case, and it comes with two hard rules.


* Methods — Reverse-flow backflush at 1.5–2× service rate, ultrasonic cleaning in mild alkaline detergent, caustic or acid CIP, and calcination or steam for carbon and polymer residues.


* Never brush or scrape — That smears the pore structure and drives contamination deeper instead of out.


* Stay inside the chloride limit — 304 will pit at the weld in chloride-bearing water long before the media fails.


* Track the clean ΔP — Once it sits 30–50% above the original baseline, the pore structure is degrading rather than fouling — the cartridge is finished.

What is the difference between nominal and absolute micron ratings on metal media?

The two words are not interchangeable, and the gap between them is where process upsets come from.


- Nominal — Means 90–95% of particles above the stated size are retained, usually with no defined test method behind the claim.


- Absolute — Means 99.9% or better, verified by a defined method — bubble point to ISO 4003, glass-bead challenge, or a recognised particulate challenge.


- Ask which method — Metal ratings are normally derived from bubble-point pore size, so the method is the number.


- Why it matters — A mesh sold as 10 µm nominal will comfortably pass 25 µm particles. Irrelevant for a coarse strainer; fatal upstream of a spin pack or a membrane.

How do I specify a metal cartridge for polymer melt filtration?

Two numbers decide whether the cartridge survives: start-up ΔP, and collapse rating against the screen changer’s maximum.


* Process data — Polymer type (PET, PP, PA6, PE), melt temperature, viscosity at that temperature, throughput in kg/h, allowable pressure build-up.


* Hardware — Screen changer, spin pack or candle housing, with its pressure rating.


* Design on start-up, not steady state — Cold polymer can produce five to ten times the service differential pressure.


* No fibre release — Sintered powder or sintered mesh, not woven cloth, downstream of an extruder.

What do you need for a custom end connection, thread or flange?

Flange standards cause more rework than any other single item on a custom order.


* Dimensions : OD, ID, overall length, thread or flange specification and bolt circle. A drawing, or a photo with a caliper in frame, is enough.


* Connection and seal : M30×1, M36×2, BSP or NPT thread, ANSI or DIN flange, quick connector, bayonet — plus seal type and material.


* Duty : Media and rating, flow, allowable ΔP, temperature, pressure, quantity.

Which filter media should I use for my dust — polyester, anti-static, fiberglass, paper or non-woven?

Match the media to the dust chemistry and to how the collector cleans. Price is the last criterion.


- Polyester needle felt — to about 130 °C — General dry dust. The default choice, and the right starting point for most collectors.


- PTFE-laminated polyester — to about 130 °C — Fine or sticky fume, where dust must not key into the depth of the felt.


- Anti-static polyester, carbon or stainless fibre — to about 130 °C — Combustible dust, and any stream where charge build-up makes the cartridge hold dust it should have released.


- Fiberglass — to about 250 °C — High temperature, and any duty requiring H13 or H14 efficiency.


- Paper or cellulose — Coarse pre-filtration where cost dominates.


- Non-woven synthetic blends — Abrasive or moisture-laden streams.

Does a higher pleat count always mean better performance?

More pleats means more area — until the pleats crowd and cleaning can no longer reach the pleat root.


* What you gain — Lower face velocity, and therefore lower differential pressure at a given flow.


* What you lose — The gaps close under load, the cartridge blinds from the inside out, and the extra area is wasted.


* The metric that matters — Pleat pitch against dust loading: fine sticky dust wants wide spacing, free-flowing granular dust tolerates tight packing.


* Also check — Pleat depth against cage inside diameter. Deep pleats in a small cartridge fold over and create a dead zone that never cleans.

Why do my cartridges fail before their rated life, and how can I extend it?

Four modes account for most premature change-outs, and the fixes sit upstream of the cartridge.


* Media burst or abrasion — High inlet velocity, a missing deflector, or pulse pressure over about 6 bar at the venturi.


* Cage collapse — Differential pressure above rating, or water ingress.


* Adhesive or gasket failure — Temperature past the glue’s limit, or solvent attack.


* Rust-through — Galvanised cages in condensing streams.

What is the difference between a coalescer filter and a separator filter?

They are two distinct technologies often used together to remove liquids from a gas or liquid stream. The key difference is their core function:

* A Coalescer Filter merges tiny, invisible liquid droplets into large, heavy ones.

* A Separator Filter catches and drains those large droplets from the flow.

How They Work:

* Coalescer: The stream passes through a special media (like fine fibers). Microscopic aerosol droplets collide and merge (coalesce) into drops large enough to drain. It solves the problem of suspended mist.

* Separator: The flow then enters a chamber with baffles or vanes. The now-large droplets hit the surfaces, fall out by gravity, and collect in a sump. It provides the final, clean separation.

When do I need fiberglass or stainless instead of polyester, and how do I handle sparks?

Above roughly 130 °C continuous, polyester is out — and the gasket and cage need checking at the same time.

* Next step up — Fiberglass holds to about 260 °C; stainless or ceramic options go further.

* The weak link changes — Often the media survives and the glue line fails first, so the temperature rating must cover the whole assembly.

* Sparks — Welding, grinding, biomass boilers, foundry: a spark arrestor or pre-settling chamber upstream is mandatory. Fiberglass resists heat, not molten metal impingement.

* Condensing streams — Acid dew point corrodes cages faster than it destroys media, and a rusted cage collapses into the fan.
373-5471699
info@huahangfilter.com
+86 16690927259

    X