Home > Products > Liquid Solution > Stainless Steel Filter Housing > Custom 304 Stainless Steel Filter Housing

Custom 304 Stainless Steel Filter Housing

Type
Stainless Steel Filter Housing
Material
SUS 304 Stainless steel
Design pressure
Customized
Filter element
1 unit
Origin
Henan,China
Connection
Quick-release eye-bolt clamp
Share:
Products Description
Specification
Features

Products Description

The 304 Stainless Steel Filter Housing is a precision-engineered filtration vessel designed for single-cartridge applications requiring corrosion resistance, sanitary construction, and reliable performance. This housing provides an ideal solution for point-of-use filtration, pilot plants, and small-scale production systems.

Constructed from high-quality 304 stainless steel, this housing offers excellent corrosion resistance for a wide range of applications, including water treatment, chemical processing, food and beverage production, and pharmaceutical manufacturing. The 106mm diameter accommodates standard 2.5-inch filter cartridges, while the 600mm height provides flexibility for elements up to 20 inches in length depending on configuration.

Specifications

Below is the specification of this single core stainless steel filter housing. Feel free to contact us for a quote.

Product type Stainless Steel Filter Housing
Material SUS 304 Stainless steel
Connection Quick-release eye-bolt clamp
Filter pressure Customized
Filter element 1 unit
Filter flow Customized
Package Neutral package

Features

Fully customizable design : Tailored to your exact specifications: dimensions, connection types and sizes, cartridge configurations, surface finishes, and seal materials.
Premium 304 Stainless Steel Construction: Provides excellent corrosion resistance for water, chemicals, food products, and pharmaceutical applications, ensuring long service life even in demanding environments.
Exceptional cleanability : Smooth internal surfaces and sanitary design options (electropolishing, passivation) enable thorough cleaning and sterilization.
Pressure Rating: Designed for operating pressures up to 1.0 MPa (10 bar / 145 psi) at ambient temperatures, suitable for most industrial and commercial applications.
Space-saving configurations : Available in single-round, multi-round, and inline configurations to optimize floor space and piping requirements.
Didn't find your industry solution? Consult our technical experts immediately.

Manufacturer & Supplier: Huahang Filter

Huahang Filter stands as a premier manufacturer and supplier in the global filtration industry. With over 20 years of specialized experience, we have honed our processes to deliver filtration solutions that combine precision engineering with cost-effectiveness.

  • 20+ Years of Industry Expertise: For more than 20 years, Huahang has been at the forefront of filter element and housing technology. This extensive history means we understand the nuances of fluid power systems and the critical nature of contamination control. Our longevity in the market is a testament to our consistent quality and customer trust.
  • Modern, Automated Production: Our manufacturing capabilities are anchored in state-of-the-art, automated production facilities. By utilizing precision CNC machining and automated welding processes, we eliminate human error and ensure that every Single Core Stainless Steel Filter Housing meets strict dimensional and performance tolerances. This automation allows for high-volume consistency and rapid turnaround times.
  • Comprehensive Customization Services: We understand that off-the-shelf solutions don’t always fit unique applications. Huahang excels in providing tailored solutions. Whether you need custom inlet/outlet sizes, special polishing requirements, alternative pressure ratings, or custom stands and accessories, our engineering team is equipped to deliver bespoke filtration products that match your exact system requirements.

FAQs of Stainless Steel Filter Housing

Q1: What is the difference between SS304 and SS316L for filter housings? Which one should I choose?
A:
SS304 is the standard grade for general water treatment, food processing, and less corrosive environments. It offers good corrosion resistance and is cost-effective.

SS316L contains molybdenum, which provides enhanced resistance to chlorides, acids, and aggressive chemicals. The “L” stands for low carbon, which improves weldability and resistance to intergranular corrosion.

Recommendation: Choose SS316L for pharmaceutical, biotechnology, seawater, and chemical injection applications. Choose SS304 for general industrial water, food & beverage (non-acidic), and light chemical duties.

Q2: How do I maintain and clean the exterior of the stainless steel housing?
A: To maintain the sanitary finish and prevent surface rust (tea staining):

Routine Cleaning: Wipe down with a soft cloth and warm soapy water or a mild detergent. Rinse thoroughly with clean water.

Passivation: For new housings or after welding, a passivation treatment (using nitric or citric acid) helps restore the protective chromium oxide layer, enhancing long-term corrosion resistance.

Avoid: Do not use steel wool or abrasive pads, as these can embed iron particles into the surface and cause rusting.

Q3: What is the maximum pressure and temperature this housing can withstand?
A: Our standard Single Core Stainless Steel Filter Housing is designed for a maximum operating pressure of 1.0 MPa (10 bar / 145 psi) . The maximum temperature depends on the seal material used, but the stainless steel structure itself can typically handle up to 300°C (572°F) . However, always check the specific pressure rating for your model, as higher pressure ratings (e.g., 2.0 MPa) can be custom manufactured.

Q4: Can this filter housing be customized to my specific requirements?

A: Yes. We offer full customization services including dimensions, connection types and sizes, cartridge capacity (1 to 20+ cartridges), element compatibility, seal materials, surface finishes, ports, and design codes. Please provide your specifications for a custom quotation.

Related Products

Related Cases

Xinxiang City Huahang Filter Co., Ltd is professional in the production of Hydraulic Filter, Air Filter and Pipe Filter.Product series range from Oil Filter, Air Filter, Water Filter, Polymer Filter,Candle Filter Element, Stainless Steel Filter to filter Coalescer and Separator.

FAQ

How do I cross-reference my existing OEM part number to a Huahang element?

Send the OEM number plus one physical measurement. A part number alone is not enough to ship against.


* What we match on — Outside diameter, inside diameter, overall height, media grade, micron rating, end-cap and seal layout, bypass setting, collapse rating and flow direction.


* When the number is ambiguous — Superseded numbers, numbers shared across several machine builds, or an element that has clearly been substituted before. In those cases a photo of the housing nameplate and a caliper reading of the old element settle it.


* Why we insist — The most common return is not a wrong size. It is an element that fits the bore but seals on the wrong face.

What collapse or burst pressure can your elements take, and how does flow direction affect it?

Collapse rating comes from the core, not the media — and it only holds in service if two conditions are met.


* Typical ranges — A light return-line element with a perforated core around 10–25 bar; a pressure-line element with a heavy spiral core 100 bar and above; high-collapse designs higher still.


* Condition 1 — flow direction — Return elements are normally outside-in. Run one backwards and the pleat pack goes into tension, folds, and bypasses.


* Condition 2 — bypass setting — The housing’s bypass valve must crack below the element’s collapse rating. Otherwise a cold start or a neglected change-out crushes the element before the valve ever opens.

Can your elements handle fire-resistant fluids such as phosphate ester and EHC systems?

Yes, but the build changes, and this is exactly where a generic replacement fails.


* Seals — Move to FKM or PTFE. NBR swells and softens in phosphate ester.


* Media and bonds — Binder, pleat-seam adhesive and end-cap adhesive all have to resist ester attack; some phenolic resin systems do not.


* Water-based fluids (HFA, HFC) — A different problem again — free water, biological growth, and media that must not delaminate when wet.


* Expect a different ΔP — These fluids run at higher viscosity and lower lubricity than mineral oil, so the same element reads differently on the gauge.

What is the difference between an oil separator element and an oil mist separator?

Same job at different pressures: one works inside a compressor separator tank, the other on a breather or vacuum pump.


* Oil separator element — Removes oil aerosol from compressed air and returns the collected oil to the sump. Rated in mg/m³ carryover, typically a few mg/m³ for a healthy element.


* Oil mist separator — Comparable duty at near-atmospheric pressure, but sized on flow and oil type rather than on pressure.


* Saturation signals, common to both — Carryover climbing, oil consumption rising with no visible leak, ΔP trending up, and an element that comes out dark and varnished instead of evenly coated.

Sintered mesh, sintered powder or pleated stainless steel — how do I choose between them?

Choose on duty, not on price. The three constructions also fail in different ways.


* Sintered mesh : 2 to 5 diffusion-bonded wire layers — High strength, genuinely backflushable, cleanable surface, absolute ratings typically 3–100 µm. Best for catalyst recovery, amine and water service, and anything cleaned in place.


* Sintered powder : A true depth filter: narrow pore distribution, finer ratings (0.5–1 µm with titanium), more dirt capacity per unit area, better resistance to compressive load. The default for polymer melt, high-pressure gas and food or pharmaceutical duty where no fibre release is allowed.


* Pleated stainless : Woven wire cloth in a pleat pack — large area and low ΔP at high flow for coarse duty, and the lowest cost per square metre of area.

How do you ensure the quality and performance of the filter element?

Quality is our lifeline. We insist on:


Strict material selection: Use high-quality raw materials that meet industry standards.


Advanced technology: Use automated or precision-controlled production processes.


Multiple quality inspections: Implement full-process quality inspections from raw material storage to finished product delivery (including size, sealing, filtration efficiency, integrity testing, etc.).


Performance testing: Key products will undergo actual working condition simulation testing.


Compliance with standards: Our production and products comply with [e.g.: ISO 9001].


Customized verification: For customized filter elements, we will confirm key performance indicators with customers and provide test reports (if necessary).

Can metal cartridges be cleaned and reused, and how many cycles should I expect?

Yes . Reusability is usually the whole economic case, and it comes with two hard rules.


* Methods — Reverse-flow backflush at 1.5–2× service rate, ultrasonic cleaning in mild alkaline detergent, caustic or acid CIP, and calcination or steam for carbon and polymer residues.


* Never brush or scrape — That smears the pore structure and drives contamination deeper instead of out.


* Stay inside the chloride limit — 304 will pit at the weld in chloride-bearing water long before the media fails.


* Track the clean ΔP — Once it sits 30–50% above the original baseline, the pore structure is degrading rather than fouling — the cartridge is finished.

What is the difference between nominal and absolute micron ratings on metal media?

The two words are not interchangeable, and the gap between them is where process upsets come from.


- Nominal — Means 90–95% of particles above the stated size are retained, usually with no defined test method behind the claim.


- Absolute — Means 99.9% or better, verified by a defined method — bubble point to ISO 4003, glass-bead challenge, or a recognised particulate challenge.


- Ask which method — Metal ratings are normally derived from bubble-point pore size, so the method is the number.


- Why it matters — A mesh sold as 10 µm nominal will comfortably pass 25 µm particles. Irrelevant for a coarse strainer; fatal upstream of a spin pack or a membrane.

How do I specify a metal cartridge for polymer melt filtration?

Two numbers decide whether the cartridge survives: start-up ΔP, and collapse rating against the screen changer’s maximum.


* Process data — Polymer type (PET, PP, PA6, PE), melt temperature, viscosity at that temperature, throughput in kg/h, allowable pressure build-up.


* Hardware — Screen changer, spin pack or candle housing, with its pressure rating.


* Design on start-up, not steady state — Cold polymer can produce five to ten times the service differential pressure.


* No fibre release — Sintered powder or sintered mesh, not woven cloth, downstream of an extruder.

What do you need for a custom end connection, thread or flange?

Flange standards cause more rework than any other single item on a custom order.


* Dimensions : OD, ID, overall length, thread or flange specification and bolt circle. A drawing, or a photo with a caliper in frame, is enough.


* Connection and seal : M30×1, M36×2, BSP or NPT thread, ANSI or DIN flange, quick connector, bayonet — plus seal type and material.


* Duty : Media and rating, flow, allowable ΔP, temperature, pressure, quantity.

Which filter media should I use for my dust — polyester, anti-static, fiberglass, paper or non-woven?

Match the media to the dust chemistry and to how the collector cleans. Price is the last criterion.


- Polyester needle felt — to about 130 °C — General dry dust. The default choice, and the right starting point for most collectors.


- PTFE-laminated polyester — to about 130 °C — Fine or sticky fume, where dust must not key into the depth of the felt.


- Anti-static polyester, carbon or stainless fibre — to about 130 °C — Combustible dust, and any stream where charge build-up makes the cartridge hold dust it should have released.


- Fiberglass — to about 250 °C — High temperature, and any duty requiring H13 or H14 efficiency.


- Paper or cellulose — Coarse pre-filtration where cost dominates.


- Non-woven synthetic blends — Abrasive or moisture-laden streams.

Does a higher pleat count always mean better performance?

More pleats means more area — until the pleats crowd and cleaning can no longer reach the pleat root.


* What you gain — Lower face velocity, and therefore lower differential pressure at a given flow.


* What you lose — The gaps close under load, the cartridge blinds from the inside out, and the extra area is wasted.


* The metric that matters — Pleat pitch against dust loading: fine sticky dust wants wide spacing, free-flowing granular dust tolerates tight packing.


* Also check — Pleat depth against cage inside diameter. Deep pleats in a small cartridge fold over and create a dead zone that never cleans.

Why do my cartridges fail before their rated life, and how can I extend it?

Four modes account for most premature change-outs, and the fixes sit upstream of the cartridge.


* Media burst or abrasion — High inlet velocity, a missing deflector, or pulse pressure over about 6 bar at the venturi.


* Cage collapse — Differential pressure above rating, or water ingress.


* Adhesive or gasket failure — Temperature past the glue’s limit, or solvent attack.


* Rust-through — Galvanised cages in condensing streams.

What is the difference between a coalescer filter and a separator filter?

They are two distinct technologies often used together to remove liquids from a gas or liquid stream. The key difference is their core function:

* A Coalescer Filter merges tiny, invisible liquid droplets into large, heavy ones.

* A Separator Filter catches and drains those large droplets from the flow.

How They Work:

* Coalescer: The stream passes through a special media (like fine fibers). Microscopic aerosol droplets collide and merge (coalesce) into drops large enough to drain. It solves the problem of suspended mist.

* Separator: The flow then enters a chamber with baffles or vanes. The now-large droplets hit the surfaces, fall out by gravity, and collect in a sump. It provides the final, clean separation.

When do I need fiberglass or stainless instead of polyester, and how do I handle sparks?

Above roughly 130 °C continuous, polyester is out — and the gasket and cage need checking at the same time.

* Next step up — Fiberglass holds to about 260 °C; stainless or ceramic options go further.

* The weak link changes — Often the media survives and the glue line fails first, so the temperature rating must cover the whole assembly.

* Sparks — Welding, grinding, biomass boilers, foundry: a spark arrestor or pre-settling chamber upstream is mandatory. Fiberglass resists heat, not molten metal impingement.

* Condensing streams — Acid dew point corrodes cages faster than it destroys media, and a rusted cage collapses into the fan.
373-5471699
info@huahangfilter.com
+86 16690927259

    X