Home > Products > Liquid Solution > Alternative Oil Filter Element > PAL Filter > HC9601FCP4H Replace Pal Oil Filter Element

HC9601FCP4H Replace Pal Oil Filter Element

Type
Replace Hydraulic Oil Filter Element
Part number
HC9601FCP4H
Filter layer
Fiberglass
Skeleton
Carbon steel punched plate
Filtration rate
1~50μm
Working temperature
-20~+110℃
Package
Neutral carton package
Share:
Products Description
Specification
Features

Products Description

The HC9601FCP4H Replace Pal Oil Filter Element, manufactured by Huahang Filter, is a high-performance aftermarket replacement element designed for Pal HC9601 series hydraulic and lubrication filtration systems . This element is engineered to provide superior fluid cleanliness by effectively removing solid particles,gelatinous contaminants, and other impurities from hydraulic fluids and lubricating oils, ensuring optimal performance and extended equipment life .

Designed for direct interchangeability, our HC9601FCP4H element fits seamlessly into existing Pal filter housings without any modifications . Utilizing advanced glass fiber filter media with a filtration rating of 6μm, it helps systems quickly achieve and maintain the desired oil cleanliness level, reducing mechanical wear and improving overall system reliability . Whether used in metallurgy, power generation, petrochemicals, or heavy industrial machinery, trusting Huahang Filter means choosing reliable and efficient filtration.

Specifications

Below is the standard specification of the replace Pal oil filter element HC9601FCP4H. Feel free to contact us for a quote.

Type Replace Hydraulic Oil Filter Element
Part number HC9601FCP4H
Filter layer Fiberglass
Skeleton Carbon steel punched plate
Filtration rate 1~50μm
Working temperature -20~+110℃
Sealing material NBR
Package Neutral carton package

Features

Direct Replacement: Manufactured to exact specifications for a perfect fit with Pal HC9601 series and other major brand filter housings .
High Filtration Efficiency: Features premium inorganic glass fiber media with filtration ratings available from 1μm to 25μm (standard 10μm configuration available), effectively removing particles from hydraulic and lubrication systems .
Robust Construction: Heavy-duty construction with structural strength ratings up to 21 MPa (210 bar) , ensuring integrity under variable flow rates and high-pressure conditions .
High Dirt-Holding Capacity: Advanced media design provides excellentdirt-holding capacity, extending service life and reducing operating costs .
Didn't find your industry solution? Consult our technical experts immediately.

Optional Part Number

There are part of the models related to the replace Pal oil filter HC9601FCP4H. If you don’t find the models you need, please don’t hesitate to consult us for a quote.

HC9600FKN13H HC9104FKS8H HC9600FCP16H HC8400FCS39H
HC9600FKZ13H HC9100FKS4H HC8900FKP13H HC8400FKN16H
HC9600FKZ16H HC9100FKT8H HC8900FKP16H HC8400FKN26H
HC9600FKP4H HC9100FKT13H HC8900FKP26H HC8400FKN39H
HC9600FKP13H HC9021FDP4H HC8900FKN8H HC8400FKS16H
HC9600FKP16H HC9021FDP8H HC8900FKN13H HC8400FKS26H
HC9600FKN4H HC9021FDT4H HC8900FKN16H HC8400FKS39H
HC9600FKN8H HC9021FDT8H HC8900FKN26H HC8400FKT8H
HC9600FKN16H HC9020FKP4H HC8900FKS8H HC8400FKT26H
HC9600FKS13H HC9020FKN8H HC8900FKS26H HC8314FKP16H

Manufacturer of Replace Oil Filter Element

Huahang Filter is not a trading company, but a true manufacturing enterprise rooted in production. From raw material warehousing to finished product delivery, every filter element is completed in our own workshop. We have served numerous industrial enterprises and encountered a variety of hydraulic filtration challenges. This experience has given us a deeper understanding of how to select the right products for our users.

Our workshop is equipped with automated folding machines, end cap forming machines, and precision testing equipment to ensure that every filter element has uniform folding, strong bonding, and accurate dimensions. We use high-quality imported glass fiber filter media to ensure stable filtration accuracy, high dirt-holding capacity, and long service life. Each filter element undergoes rigorous testing, and its quality meets or exceeds OEM standards without affecting normal use.

  • Experienced Technical Team – Our engineers understand the challenges of different hydraulic applications—from high-pressure mobile equipment to precision industrial machinery. This knowledge helps us recommend the right product for your specific needs.
  • Direct Replacement Design – We manufacture our elements to match original Pal specifications exactly, ensuring perfect fit and function in your existing filter housing. No modifications, no compatibility issues.
  • Flexible Quantities – Whether you need a single element for maintenance or regular production volumes, we can accommodate your requirements.
  • Quality Raw Materials – We source our glass fiber media from reputable suppliers known for consistent quality. The media we use provides the filtration efficiency, dirt-holding capacity, and structural integrity required for demanding hydraulic applications .

FAQ

Q1: Is this HC9601FCP4H element a genuine Pal part?
A: No, this is a high-quality replacement element manufactured by Huahang Filter. It is designed to be completely interchangeable with the original Pal HC9601FCP4H element and meets or exceeds the original performance specifications .

Q2: What is the filtration rating of this HC9601FCP4H element?
A: Our standard HC9601FCP4H element features a filtration rating of 6 microns . We also offer alternative ratings including 1μm, 3μm, 12μm, and 25μm depending on your specific requirements .

Q3: What industries commonly use this HC9601FCP4H filter element?
A: This element is widely used in metallurgy (rolling mills, continuous casting machines), power generation (turbines, boilers), petrochemical processing, and various industrial hydraulic systems requiring high-flow filtration .

Q4: Can this filter element be cleaned and reused?
A: Yes. Select configurations of the HC9601FCP4H support cleaning and reuse. The element can be cleaned and reused when appropriate cleaning methods are applied, offering extended service life and reduced operating costs . However, always inspect the element thoroughly after cleaning to ensure no damage has occurred.

Q5: What is the maximum operating pressure for this element?
A: The HC9601FCP4H filter element is designed to withstand operating pressures up to 32-42 MPa (320-420 bar) depending on the specific configuration and structural strength rating .

Related Products

Related Cases

Xinxiang City Huahang Filter Co., Ltd is professional in the production of Hydraulic Filter, Air Filter and Pipe Filter.Product series range from Oil Filter, Air Filter, Water Filter, Polymer Filter,Candle Filter Element, Stainless Steel Filter to filter Coalescer and Separator.

FAQ

How do I cross-reference my existing OEM part number to a Huahang element?

Send the OEM number plus one physical measurement. A part number alone is not enough to ship against.


* What we match on — Outside diameter, inside diameter, overall height, media grade, micron rating, end-cap and seal layout, bypass setting, collapse rating and flow direction.


* When the number is ambiguous — Superseded numbers, numbers shared across several machine builds, or an element that has clearly been substituted before. In those cases a photo of the housing nameplate and a caliper reading of the old element settle it.


* Why we insist — The most common return is not a wrong size. It is an element that fits the bore but seals on the wrong face.

What collapse or burst pressure can your elements take, and how does flow direction affect it?

Collapse rating comes from the core, not the media — and it only holds in service if two conditions are met.


* Typical ranges — A light return-line element with a perforated core around 10–25 bar; a pressure-line element with a heavy spiral core 100 bar and above; high-collapse designs higher still.


* Condition 1 — flow direction — Return elements are normally outside-in. Run one backwards and the pleat pack goes into tension, folds, and bypasses.


* Condition 2 — bypass setting — The housing’s bypass valve must crack below the element’s collapse rating. Otherwise a cold start or a neglected change-out crushes the element before the valve ever opens.

Can your elements handle fire-resistant fluids such as phosphate ester and EHC systems?

Yes, but the build changes, and this is exactly where a generic replacement fails.


* Seals — Move to FKM or PTFE. NBR swells and softens in phosphate ester.


* Media and bonds — Binder, pleat-seam adhesive and end-cap adhesive all have to resist ester attack; some phenolic resin systems do not.


* Water-based fluids (HFA, HFC) — A different problem again — free water, biological growth, and media that must not delaminate when wet.


* Expect a different ΔP — These fluids run at higher viscosity and lower lubricity than mineral oil, so the same element reads differently on the gauge.

What is the difference between an oil separator element and an oil mist separator?

Same job at different pressures: one works inside a compressor separator tank, the other on a breather or vacuum pump.


* Oil separator element — Removes oil aerosol from compressed air and returns the collected oil to the sump. Rated in mg/m³ carryover, typically a few mg/m³ for a healthy element.


* Oil mist separator — Comparable duty at near-atmospheric pressure, but sized on flow and oil type rather than on pressure.


* Saturation signals, common to both — Carryover climbing, oil consumption rising with no visible leak, ΔP trending up, and an element that comes out dark and varnished instead of evenly coated.

Sintered mesh, sintered powder or pleated stainless steel — how do I choose between them?

Choose on duty, not on price. The three constructions also fail in different ways.


* Sintered mesh : 2 to 5 diffusion-bonded wire layers — High strength, genuinely backflushable, cleanable surface, absolute ratings typically 3–100 µm. Best for catalyst recovery, amine and water service, and anything cleaned in place.


* Sintered powder : A true depth filter: narrow pore distribution, finer ratings (0.5–1 µm with titanium), more dirt capacity per unit area, better resistance to compressive load. The default for polymer melt, high-pressure gas and food or pharmaceutical duty where no fibre release is allowed.


* Pleated stainless : Woven wire cloth in a pleat pack — large area and low ΔP at high flow for coarse duty, and the lowest cost per square metre of area.

How do you ensure the quality and performance of the filter element?

Quality is our lifeline. We insist on:


Strict material selection: Use high-quality raw materials that meet industry standards.


Advanced technology: Use automated or precision-controlled production processes.


Multiple quality inspections: Implement full-process quality inspections from raw material storage to finished product delivery (including size, sealing, filtration efficiency, integrity testing, etc.).


Performance testing: Key products will undergo actual working condition simulation testing.


Compliance with standards: Our production and products comply with [e.g.: ISO 9001].


Customized verification: For customized filter elements, we will confirm key performance indicators with customers and provide test reports (if necessary).

Can metal cartridges be cleaned and reused, and how many cycles should I expect?

Yes . Reusability is usually the whole economic case, and it comes with two hard rules.


* Methods — Reverse-flow backflush at 1.5–2× service rate, ultrasonic cleaning in mild alkaline detergent, caustic or acid CIP, and calcination or steam for carbon and polymer residues.


* Never brush or scrape — That smears the pore structure and drives contamination deeper instead of out.


* Stay inside the chloride limit — 304 will pit at the weld in chloride-bearing water long before the media fails.


* Track the clean ΔP — Once it sits 30–50% above the original baseline, the pore structure is degrading rather than fouling — the cartridge is finished.

What is the difference between nominal and absolute micron ratings on metal media?

The two words are not interchangeable, and the gap between them is where process upsets come from.


- Nominal — Means 90–95% of particles above the stated size are retained, usually with no defined test method behind the claim.


- Absolute — Means 99.9% or better, verified by a defined method — bubble point to ISO 4003, glass-bead challenge, or a recognised particulate challenge.


- Ask which method — Metal ratings are normally derived from bubble-point pore size, so the method is the number.


- Why it matters — A mesh sold as 10 µm nominal will comfortably pass 25 µm particles. Irrelevant for a coarse strainer; fatal upstream of a spin pack or a membrane.

How do I specify a metal cartridge for polymer melt filtration?

Two numbers decide whether the cartridge survives: start-up ΔP, and collapse rating against the screen changer’s maximum.


* Process data — Polymer type (PET, PP, PA6, PE), melt temperature, viscosity at that temperature, throughput in kg/h, allowable pressure build-up.


* Hardware — Screen changer, spin pack or candle housing, with its pressure rating.


* Design on start-up, not steady state — Cold polymer can produce five to ten times the service differential pressure.


* No fibre release — Sintered powder or sintered mesh, not woven cloth, downstream of an extruder.

What do you need for a custom end connection, thread or flange?

Flange standards cause more rework than any other single item on a custom order.


* Dimensions : OD, ID, overall length, thread or flange specification and bolt circle. A drawing, or a photo with a caliper in frame, is enough.


* Connection and seal : M30×1, M36×2, BSP or NPT thread, ANSI or DIN flange, quick connector, bayonet — plus seal type and material.


* Duty : Media and rating, flow, allowable ΔP, temperature, pressure, quantity.

Which filter media should I use for my dust — polyester, anti-static, fiberglass, paper or non-woven?

Match the media to the dust chemistry and to how the collector cleans. Price is the last criterion.


- Polyester needle felt — to about 130 °C — General dry dust. The default choice, and the right starting point for most collectors.


- PTFE-laminated polyester — to about 130 °C — Fine or sticky fume, where dust must not key into the depth of the felt.


- Anti-static polyester, carbon or stainless fibre — to about 130 °C — Combustible dust, and any stream where charge build-up makes the cartridge hold dust it should have released.


- Fiberglass — to about 250 °C — High temperature, and any duty requiring H13 or H14 efficiency.


- Paper or cellulose — Coarse pre-filtration where cost dominates.


- Non-woven synthetic blends — Abrasive or moisture-laden streams.

Does a higher pleat count always mean better performance?

More pleats means more area — until the pleats crowd and cleaning can no longer reach the pleat root.


* What you gain — Lower face velocity, and therefore lower differential pressure at a given flow.


* What you lose — The gaps close under load, the cartridge blinds from the inside out, and the extra area is wasted.


* The metric that matters — Pleat pitch against dust loading: fine sticky dust wants wide spacing, free-flowing granular dust tolerates tight packing.


* Also check — Pleat depth against cage inside diameter. Deep pleats in a small cartridge fold over and create a dead zone that never cleans.

Why do my cartridges fail before their rated life, and how can I extend it?

Four modes account for most premature change-outs, and the fixes sit upstream of the cartridge.


* Media burst or abrasion — High inlet velocity, a missing deflector, or pulse pressure over about 6 bar at the venturi.


* Cage collapse — Differential pressure above rating, or water ingress.


* Adhesive or gasket failure — Temperature past the glue’s limit, or solvent attack.


* Rust-through — Galvanised cages in condensing streams.

What is the difference between a coalescer filter and a separator filter?

They are two distinct technologies often used together to remove liquids from a gas or liquid stream. The key difference is their core function:

* A Coalescer Filter merges tiny, invisible liquid droplets into large, heavy ones.

* A Separator Filter catches and drains those large droplets from the flow.

How They Work:

* Coalescer: The stream passes through a special media (like fine fibers). Microscopic aerosol droplets collide and merge (coalesce) into drops large enough to drain. It solves the problem of suspended mist.

* Separator: The flow then enters a chamber with baffles or vanes. The now-large droplets hit the surfaces, fall out by gravity, and collect in a sump. It provides the final, clean separation.

When do I need fiberglass or stainless instead of polyester, and how do I handle sparks?

Above roughly 130 °C continuous, polyester is out — and the gasket and cage need checking at the same time.

* Next step up — Fiberglass holds to about 260 °C; stainless or ceramic options go further.

* The weak link changes — Often the media survives and the glue line fails first, so the temperature rating must cover the whole assembly.

* Sparks — Welding, grinding, biomass boilers, foundry: a spark arrestor or pre-settling chamber upstream is mandatory. Fiberglass resists heat, not molten metal impingement.

* Condensing streams — Acid dew point corrodes cages faster than it destroys media, and a rusted cage collapses into the fan.
373-5471699
info@huahangfilter.com
+86 16690927259