Home > Products > Liquid Solution > Alternative Oil Filter Element > PAL Filter > HC9800FCN8H Replace Pal Oil Filter Element

HC9800FCN8H Replace Pal Oil Filter Element

Type
Replace Hydraulic Oil Filter Element
Part number
HC9800FCN8H
Filter layer
Fiberglass
End caps
Carbon steel
Filtration rate
1~50μm
Working temperature
-20~+110℃
Package
Neutral carton package
Share:
Products Description
Specification
Features

Products Description

The HC9800FCN8H Replace Pal Oil Filter Element is a direct, high-performance alternative to the original Pal HC9800 series filter, designed for Pal filter housings in hydraulic and lube systems. Featuring glass fiber media with stress-resistant technology, this filter delivers high efficiency , depth-loading filtration for high dirt-holding capacity, and longer service life than surface‑loading alternatives.

Compatible with mineral oils, synthetics, phosphate esters, and water‑glycol fluids, it is widely used in power generation, steel mills, industrial manufacturing, and marine hydraulics—providing OEM‑grade protection at a cost‑effective price.

 

Specifications

Below is the standard specification of the replace Pal oil filter element HC9800FCN8H. Feel free to contact us for a quote.

Type Replace Hydraulic Oil Filter Element
Part number HC9800FCN8H
Filter layer Fiberglass
End caps Carbon steel
Filtration rate 1~50μm
Working temperature -20~+110℃
Sealing material NBR
Package Neutral carton package

Features

Direct Replacement: Manufactured to exact specifications for a perfect fit with Pal HC9800 series and other major brand filter housings .
High Filtration Efficiency: Features premium inorganic glass fiber media with filtration ratings available from 1μm to 50μm, effectively removing particles from hydraulic and lubrication systems .
Low Clean Pressure Drop: Efficient media design ensures minimal flow resistance, reducing energy consumption.
High Dirt-Holding Capacity: Advanced media design provides excellentdirt-holding capacity, extending service life and reducing operating costs .
Didn't find your industry solution? Consult our technical experts immediately.

Optional Part Number

There are part of the models related to the replace Pal oil filter HC9600FKT4H. If you don’t find the models you need, please don’t hesitate to consult us for a quote.

HC9800FKS4H HC9600FKT4H HC8300FRN26Z HC8400FKP8H
HC9800FKT8H HC9100FKN13H HC8904FKT26H HC8400FKP16H
HC9600FKZ8H HC9100FKS13H HC8900FKP8H HC8400FKN8H
HC9600FKZ13H HC9100FKS4H HC8900FKP13H HC8400FKN16H
HC9600FKZ16H HC9100FKT8H HC8900FKP16H HC8400FKN26H
HC9600FKP4H HC9100FKT13H HC8900FKP26H HC8400FKN39H
HC9600FKP13H HC9021FDP4H HC8900FKN8H HC8400FKS16H
HC9600FKP16H HC9021FDP8H HC8900FKN13H HC8400FKS26H
HC9600FKN4H HC9021FDT4H HC8900FKN16H HC8400FKS39H
HC9600FKN8H HC9021FDT8H HC8900FKN26H HC8400FKT8H
HC9600FKN16H HC9020FKP4H HC8900FKS8H HC8400FKT26H
HC9600FKS13H HC9020FKN8H HC8900FKS26H HC8314FKP16H

Manufacturer of Replace Oil Filter Element

Huahang Filter is not a trading company, but a true manufacturing enterprise rooted in production. From raw material warehousing to finished product delivery, every filter element is completed in our own workshop. We have served numerous industrial enterprises and encountered a variety of hydraulic filtration challenges. This experience has given us a deeper understanding of how to select the right products for our users.

Our workshop is equipped with automated folding machines, end cap forming machines, and precision testing equipment to ensure that every filter element has uniform folding, strong bonding, and accurate dimensions. We use high-quality imported glass fiber filter media to ensure stable filtration accuracy, high dirt-holding capacity, and long service life. Each filter element undergoes rigorous testing, and its quality meets or exceeds OEM standards without affecting normal use.

Why Choose Huahang Filter

  • Experienced Technical Team – Our engineers understand the challenges of different hydraulic applications—from high-pressure mobile equipment to precision industrial machinery. This knowledge helps us recommend the right product for your specific needs.
  • Direct Replacement Design – We manufacture our elements to match original Pal specifications exactly, ensuring perfect fit and function in your existing filter housing. No modifications, no compatibility issues.
  • Flexible Quantities – Whether you need a single filter element for maintenance or regular production volumes, we can accommodate your requirements.
  • Quality Raw Materials – We source our glass fiber media from reputable suppliers known for consistent quality. The media we use provides the filtration efficiency, dirt-holding capacity, and structural integrity required for demanding hydraulic applications .

FAQ

Q: How can I confirm this HC9800FCN8H filter will fit my Pal housing?
A: Verify the OEM part number HC9800FCN8H is listed in your equipment manual or on the filter currently installed. Our team can cross-reference if you provide a drawing, sample, or detailed measurements.

Q. What type of fluid can I use with this filter element?
A: The HC9800FCN8H replace oil filter is compatible with a wide range of industrial fluids. This includes petroleum-based hydraulic oils, water glycols, water-oil emulsions, phosphate ester fluids, and most synthetic lubricants . Always verify seal material compatibility with your specific fluid, especially with exotic synthetics.

Q. How often should I replace this hydraulic filter element?
A: Replacement intervals depend on your system’s operating conditions and the level of contamination in the environment. A good rule of thumb is to replace the element during scheduled maintenance or when a differential pressure indicator signals that the element is becoming clogged . Regular replacement ensures that your system maintains target cleanliness levels and protects sensitive components like servo valves and pumps.

Q. Can this filter be used in high-pressure applications?
A: Yes. The HC9800FCN8H replace oil filter features a high-strength design with a collapse pressure rating of up to 210 bar  . This makes it suitable for installation in pressure lines where flow and pressure surges are common, ensuring the element maintains its structure and continues to filter effectively.

Q. What industries typically use the HC9800FCN8H filter?
A: This filter is a common choice in steel mills, power generation facilities, mining operations, and heavy industrial manufacturing . Anywhere you have hydraulic power units, lubrication consoles, or mobile hydraulic equipment, you’ll likely find this style of filter protecting the system.

Related Products

Related Cases

Xinxiang City Huahang Filter Co., Ltd is professional in the production of Hydraulic Filter, Air Filter and Pipe Filter.Product series range from Oil Filter, Air Filter, Water Filter, Polymer Filter,Candle Filter Element, Stainless Steel Filter to filter Coalescer and Separator.

FAQ

How do I cross-reference my existing OEM part number to a Huahang element?

Send the OEM number plus one physical measurement. A part number alone is not enough to ship against.


* What we match on — Outside diameter, inside diameter, overall height, media grade, micron rating, end-cap and seal layout, bypass setting, collapse rating and flow direction.


* When the number is ambiguous — Superseded numbers, numbers shared across several machine builds, or an element that has clearly been substituted before. In those cases a photo of the housing nameplate and a caliper reading of the old element settle it.


* Why we insist — The most common return is not a wrong size. It is an element that fits the bore but seals on the wrong face.

What collapse or burst pressure can your elements take, and how does flow direction affect it?

Collapse rating comes from the core, not the media — and it only holds in service if two conditions are met.


* Typical ranges — A light return-line element with a perforated core around 10–25 bar; a pressure-line element with a heavy spiral core 100 bar and above; high-collapse designs higher still.


* Condition 1 — flow direction — Return elements are normally outside-in. Run one backwards and the pleat pack goes into tension, folds, and bypasses.


* Condition 2 — bypass setting — The housing’s bypass valve must crack below the element’s collapse rating. Otherwise a cold start or a neglected change-out crushes the element before the valve ever opens.

Can your elements handle fire-resistant fluids such as phosphate ester and EHC systems?

Yes, but the build changes, and this is exactly where a generic replacement fails.


* Seals — Move to FKM or PTFE. NBR swells and softens in phosphate ester.


* Media and bonds — Binder, pleat-seam adhesive and end-cap adhesive all have to resist ester attack; some phenolic resin systems do not.


* Water-based fluids (HFA, HFC) — A different problem again — free water, biological growth, and media that must not delaminate when wet.


* Expect a different ΔP — These fluids run at higher viscosity and lower lubricity than mineral oil, so the same element reads differently on the gauge.

What is the difference between an oil separator element and an oil mist separator?

Same job at different pressures: one works inside a compressor separator tank, the other on a breather or vacuum pump.


* Oil separator element — Removes oil aerosol from compressed air and returns the collected oil to the sump. Rated in mg/m³ carryover, typically a few mg/m³ for a healthy element.


* Oil mist separator — Comparable duty at near-atmospheric pressure, but sized on flow and oil type rather than on pressure.


* Saturation signals, common to both — Carryover climbing, oil consumption rising with no visible leak, ΔP trending up, and an element that comes out dark and varnished instead of evenly coated.

Sintered mesh, sintered powder or pleated stainless steel — how do I choose between them?

Choose on duty, not on price. The three constructions also fail in different ways.


* Sintered mesh : 2 to 5 diffusion-bonded wire layers — High strength, genuinely backflushable, cleanable surface, absolute ratings typically 3–100 µm. Best for catalyst recovery, amine and water service, and anything cleaned in place.


* Sintered powder : A true depth filter: narrow pore distribution, finer ratings (0.5–1 µm with titanium), more dirt capacity per unit area, better resistance to compressive load. The default for polymer melt, high-pressure gas and food or pharmaceutical duty where no fibre release is allowed.


* Pleated stainless : Woven wire cloth in a pleat pack — large area and low ΔP at high flow for coarse duty, and the lowest cost per square metre of area.

How do you ensure the quality and performance of the filter element?

Quality is our lifeline. We insist on:


Strict material selection: Use high-quality raw materials that meet industry standards.


Advanced technology: Use automated or precision-controlled production processes.


Multiple quality inspections: Implement full-process quality inspections from raw material storage to finished product delivery (including size, sealing, filtration efficiency, integrity testing, etc.).


Performance testing: Key products will undergo actual working condition simulation testing.


Compliance with standards: Our production and products comply with [e.g.: ISO 9001].


Customized verification: For customized filter elements, we will confirm key performance indicators with customers and provide test reports (if necessary).

Can metal cartridges be cleaned and reused, and how many cycles should I expect?

Yes . Reusability is usually the whole economic case, and it comes with two hard rules.


* Methods — Reverse-flow backflush at 1.5–2× service rate, ultrasonic cleaning in mild alkaline detergent, caustic or acid CIP, and calcination or steam for carbon and polymer residues.


* Never brush or scrape — That smears the pore structure and drives contamination deeper instead of out.


* Stay inside the chloride limit — 304 will pit at the weld in chloride-bearing water long before the media fails.


* Track the clean ΔP — Once it sits 30–50% above the original baseline, the pore structure is degrading rather than fouling — the cartridge is finished.

What is the difference between nominal and absolute micron ratings on metal media?

The two words are not interchangeable, and the gap between them is where process upsets come from.


- Nominal — Means 90–95% of particles above the stated size are retained, usually with no defined test method behind the claim.


- Absolute — Means 99.9% or better, verified by a defined method — bubble point to ISO 4003, glass-bead challenge, or a recognised particulate challenge.


- Ask which method — Metal ratings are normally derived from bubble-point pore size, so the method is the number.


- Why it matters — A mesh sold as 10 µm nominal will comfortably pass 25 µm particles. Irrelevant for a coarse strainer; fatal upstream of a spin pack or a membrane.

How do I specify a metal cartridge for polymer melt filtration?

Two numbers decide whether the cartridge survives: start-up ΔP, and collapse rating against the screen changer’s maximum.


* Process data — Polymer type (PET, PP, PA6, PE), melt temperature, viscosity at that temperature, throughput in kg/h, allowable pressure build-up.


* Hardware — Screen changer, spin pack or candle housing, with its pressure rating.


* Design on start-up, not steady state — Cold polymer can produce five to ten times the service differential pressure.


* No fibre release — Sintered powder or sintered mesh, not woven cloth, downstream of an extruder.

What do you need for a custom end connection, thread or flange?

Flange standards cause more rework than any other single item on a custom order.


* Dimensions : OD, ID, overall length, thread or flange specification and bolt circle. A drawing, or a photo with a caliper in frame, is enough.


* Connection and seal : M30×1, M36×2, BSP or NPT thread, ANSI or DIN flange, quick connector, bayonet — plus seal type and material.


* Duty : Media and rating, flow, allowable ΔP, temperature, pressure, quantity.

Which filter media should I use for my dust — polyester, anti-static, fiberglass, paper or non-woven?

Match the media to the dust chemistry and to how the collector cleans. Price is the last criterion.


- Polyester needle felt — to about 130 °C — General dry dust. The default choice, and the right starting point for most collectors.


- PTFE-laminated polyester — to about 130 °C — Fine or sticky fume, where dust must not key into the depth of the felt.


- Anti-static polyester, carbon or stainless fibre — to about 130 °C — Combustible dust, and any stream where charge build-up makes the cartridge hold dust it should have released.


- Fiberglass — to about 250 °C — High temperature, and any duty requiring H13 or H14 efficiency.


- Paper or cellulose — Coarse pre-filtration where cost dominates.


- Non-woven synthetic blends — Abrasive or moisture-laden streams.

Does a higher pleat count always mean better performance?

More pleats means more area — until the pleats crowd and cleaning can no longer reach the pleat root.


* What you gain — Lower face velocity, and therefore lower differential pressure at a given flow.


* What you lose — The gaps close under load, the cartridge blinds from the inside out, and the extra area is wasted.


* The metric that matters — Pleat pitch against dust loading: fine sticky dust wants wide spacing, free-flowing granular dust tolerates tight packing.


* Also check — Pleat depth against cage inside diameter. Deep pleats in a small cartridge fold over and create a dead zone that never cleans.

Why do my cartridges fail before their rated life, and how can I extend it?

Four modes account for most premature change-outs, and the fixes sit upstream of the cartridge.


* Media burst or abrasion — High inlet velocity, a missing deflector, or pulse pressure over about 6 bar at the venturi.


* Cage collapse — Differential pressure above rating, or water ingress.


* Adhesive or gasket failure — Temperature past the glue’s limit, or solvent attack.


* Rust-through — Galvanised cages in condensing streams.

What is the difference between a coalescer filter and a separator filter?

They are two distinct technologies often used together to remove liquids from a gas or liquid stream. The key difference is their core function:

* A Coalescer Filter merges tiny, invisible liquid droplets into large, heavy ones.

* A Separator Filter catches and drains those large droplets from the flow.

How They Work:

* Coalescer: The stream passes through a special media (like fine fibers). Microscopic aerosol droplets collide and merge (coalesce) into drops large enough to drain. It solves the problem of suspended mist.

* Separator: The flow then enters a chamber with baffles or vanes. The now-large droplets hit the surfaces, fall out by gravity, and collect in a sump. It provides the final, clean separation.

When do I need fiberglass or stainless instead of polyester, and how do I handle sparks?

Above roughly 130 °C continuous, polyester is out — and the gasket and cage need checking at the same time.

* Next step up — Fiberglass holds to about 260 °C; stainless or ceramic options go further.

* The weak link changes — Often the media survives and the glue line fails first, so the temperature rating must cover the whole assembly.

* Sparks — Welding, grinding, biomass boilers, foundry: a spark arrestor or pre-settling chamber upstream is mandatory. Fiberglass resists heat, not molten metal impingement.

* Condensing streams — Acid dew point corrodes cages faster than it destroys media, and a rusted cage collapses into the fan.
373-5471699
info@huahangfilter.com
+86 16690927259

    X