Home > Products > Liquid Solution > Oil Purifier > LYC-A25 Portable Oil Purifier

LYC-A25 Portable Oil Purifier

Type
Oil Purifier
Rated flow rate
25 L/min
Rated pressure
0.6 Mpa
Working temperature
5 ~80 ℃
Filtration rate
3, 5 ,10 , 20 ,40 μm
Origin
Henan, China
Share:
Products Description
Specification
Features

Products Description

The LYC-A25 portable oil purifier is a compact, high-efficiency oil filtration system designed for on-site purification of hydraulic fluids, lubricating oils, and other industrial oils. With a rated flow of 25 L/min, this portable unit delivers reliable, cost-effective oil cleaning for a wide range of applications including new oil filtration, system oil addition, in-service oil purification, and hydraulic system bypass filtration.

Engineered with a motor-driven dedicated gear pump, the LYC-A25 features low noise operation, strong self-priming capability, and smooth, stable performance. The unit employs a dual-stage filtration system — a 100μm coarse inlet filter protects the pump and extends main filter life, while a precision filter (available in 3μm, 5μm, 10μm, 20μm, or 40μm) removes fine particulate contaminants to restore oil to cleanliness standards.

Specification of LYC-A Series Oil Purifier

Part number LYC-A25-*/** LYC-A32-*/** LYC-A40-*/** LYC-A50-*/** LYC-A63-*/** LYC-A100-*/** LYC-A150-*/**
Rated flow rate(L/min) 25 32 40 50 63 100 150
Rated pressure (Mpa) 0.6
Initial pressure loss (Mpa) ≤0.01
Coarse filtration rate (μm) 100
Fine filtration rate (μm) 3/5/10/20/40
Working temperature (℃) 5~80
Filter element replacement differential pressure 0.2 Mpa

Note: *—Filtration rating (e.g., 03 = 3 microns)
**—Filtration medium; omit for standard hydraulic oil; BH: Water-glycol; V: Phosphate ester fluid
***—Explosion-proof type: Add “F” before the model number; omit for standard type

Features

Compact and portable design – Lightweight (35kg) with rugged frame and casters for easy maneuvering around the plant floor.
Quiet, reliable gear pump – Motor-driven dedicated gear pump delivers low noise, strong self-priming capability, and smooth, stable operation.
Dual-stage filtration system – 100μm coarse inlet filter protects the pump from large debris, while precision filter (3–40μm) removes fine particulates to achieve cleanliness standards.
Quick-open filter housing – Tool-free access to the filter element allows fast, convenient replacement without special tools.
Overload protection – Thermal relay protects the motor from damage caused by overloading, ensuring long-term reliability.
Overflow safety protection – High-pressure line overflow protection device prevents system over-pressurization and safeguards hydraulic system safety.
Didn't find your industry solution? Consult our technical experts immediately.

Manufacturer & Supplier

Xinxiang City Huahang Filter Co., Ltd. is an ISO 9001 certified professional manufacturer specializing in the design, production, and sale of hydraulic filter elements, replacement filters, and industrial filtration solutions. Established in 2003, the company operates from a modern manufacturing facility in Xinxiang City, Henan Province – one of China’s most established filtration industry clusters.

Our workshop is equipped with automated paper folding machines, end cap assembly lines, and testing equipment to ensure consistent quality across every batch. Most of our workers have many years of experience here, familiar with every stage of production. We believe that good products stem from a dedicated attitude and solid craftsmanship.

Why Choose Huahang Filter

  • 20+ Years of Filtration Expertise : Since 2003, Huahang has specialized in hydraulic filter elements for industrial applications worldwide.
  • Cost‑Effective Filtration Solution : Paper media offers the most economical option for hydraulic systems requiring moderate filtration accuracy.
  • Full Customization with Low MOQ : Any outer diameter, any length, any micron rating (1‑100 μm), any end cap material, any seal material. From a single prototype to production quantities.
  • Multiple Folding and Support Options : Conventional folding, high‑density folding, inner core, outer core, or double core support structures available.

Application

The LYC-A25 Portable Oil Purifier is widely used across multiple industries and applications:

  • New Oil Filtration: Filters new oil before it is added to systems, removing contaminants introduced during storage and transportation

  • System Oil Addition: Filters oil while adding to hydraulic or lubrication systems, ensuring only clean oil enters the equipment

  • In-Service Oil Purification: Cleans oil that is currently in use, removing accumulated contaminants and extending oil life

  • Hydraulic System Bypass Filtration: Operates as a parallel filtration loop independent of the main system, providing continuous oil cleaning

  • Pre-Commissioning System Flushing: Circulates and filters oil through new or repaired systems before startup to remove debris

  • Industrial Machinery: Hydraulic system maintenance for presses, CNC machines, gearboxes, and turbines

  • Power Generation: Transformer oil purification and turbine lubrication system conditioning

  • Mobile Equipment: Fluid servicing for marine, mining, and construction equipment hydraulic systems

  • Precision Manufacturing: Injection molding machine oil recycling and aerospace hydraulic fluid polishing

Working Principle

The LYC-A25 Portable Oil Purifier operates through a straightforward, effective two-stage filtration process:

Stage 1 – Coarse Filtration (100μm): Contaminated oil is drawn into the unit by the gear pump through an inlet strainer that captures large debris (≥100μm), protecting the pump and downstream components from damage.

Stage 2 – Precision Filtration (3–40μm): The oil then passes through the precision filter element, where graded-depth media removes fine particulate contaminants. The filtration accuracy can be selected based on application requirements — from 3μm for high-precision systems to 40μm for general industrial use.

Real-Time Monitoring: A pressure gauge on the panel continuously displays the system pressure. An increase in differential pressure indicates filter saturation — replace the element when ΔP reaches 0.2 MPa.

Clean Oil Return: Purified oil is returned to the reservoir or equipment through the outlet, ready for use.

FAQ

Q1: What types of oil can the LYC-A25 filter?
A: The LYC-A25 is suitable for hydraulic oil, lubricating oil, transformer oil, gear oil, and other petroleum-based mineral oils. It can also handle fire-resistant fluids such as water-glycol (BH) and phosphate ester (V) with appropriate configurations.

Q: Can the LYC-A25 be used as a bypass filter?
A: Yes. The unit can be connected in parallel to an existing hydraulic or lubrication system as a bypass filtration loop, providing continuous oil cleaning without interrupting normal system operation.

Q: Is the LYC-A25 suitable for transformer oil?
A: Yes. The LYC-A25 can be used for transformer oil purification. For applications requiring degassing and dehydration, please consult us for specialized equipment.

Related Products

Related Cases

Xinxiang City Huahang Filter Co., Ltd is professional in the production of Hydraulic Filter, Air Filter and Pipe Filter.Product series range from Oil Filter, Air Filter, Water Filter, Polymer Filter,Candle Filter Element, Stainless Steel Filter to filter Coalescer and Separator.

FAQ

How do I cross-reference my existing OEM part number to a Huahang element?

Send the OEM number plus one physical measurement. A part number alone is not enough to ship against.


* What we match on — Outside diameter, inside diameter, overall height, media grade, micron rating, end-cap and seal layout, bypass setting, collapse rating and flow direction.


* When the number is ambiguous — Superseded numbers, numbers shared across several machine builds, or an element that has clearly been substituted before. In those cases a photo of the housing nameplate and a caliper reading of the old element settle it.


* Why we insist — The most common return is not a wrong size. It is an element that fits the bore but seals on the wrong face.

What collapse or burst pressure can your elements take, and how does flow direction affect it?

Collapse rating comes from the core, not the media — and it only holds in service if two conditions are met.


* Typical ranges — A light return-line element with a perforated core around 10–25 bar; a pressure-line element with a heavy spiral core 100 bar and above; high-collapse designs higher still.


* Condition 1 — flow direction — Return elements are normally outside-in. Run one backwards and the pleat pack goes into tension, folds, and bypasses.


* Condition 2 — bypass setting — The housing’s bypass valve must crack below the element’s collapse rating. Otherwise a cold start or a neglected change-out crushes the element before the valve ever opens.

Can your elements handle fire-resistant fluids such as phosphate ester and EHC systems?

Yes, but the build changes, and this is exactly where a generic replacement fails.


* Seals — Move to FKM or PTFE. NBR swells and softens in phosphate ester.


* Media and bonds — Binder, pleat-seam adhesive and end-cap adhesive all have to resist ester attack; some phenolic resin systems do not.


* Water-based fluids (HFA, HFC) — A different problem again — free water, biological growth, and media that must not delaminate when wet.


* Expect a different ΔP — These fluids run at higher viscosity and lower lubricity than mineral oil, so the same element reads differently on the gauge.

What is the difference between an oil separator element and an oil mist separator?

Same job at different pressures: one works inside a compressor separator tank, the other on a breather or vacuum pump.


* Oil separator element — Removes oil aerosol from compressed air and returns the collected oil to the sump. Rated in mg/m³ carryover, typically a few mg/m³ for a healthy element.


* Oil mist separator — Comparable duty at near-atmospheric pressure, but sized on flow and oil type rather than on pressure.


* Saturation signals, common to both — Carryover climbing, oil consumption rising with no visible leak, ΔP trending up, and an element that comes out dark and varnished instead of evenly coated.

Sintered mesh, sintered powder or pleated stainless steel — how do I choose between them?

Choose on duty, not on price. The three constructions also fail in different ways.


* Sintered mesh : 2 to 5 diffusion-bonded wire layers — High strength, genuinely backflushable, cleanable surface, absolute ratings typically 3–100 µm. Best for catalyst recovery, amine and water service, and anything cleaned in place.


* Sintered powder : A true depth filter: narrow pore distribution, finer ratings (0.5–1 µm with titanium), more dirt capacity per unit area, better resistance to compressive load. The default for polymer melt, high-pressure gas and food or pharmaceutical duty where no fibre release is allowed.


* Pleated stainless : Woven wire cloth in a pleat pack — large area and low ΔP at high flow for coarse duty, and the lowest cost per square metre of area.

How do you ensure the quality and performance of the filter element?

Quality is our lifeline. We insist on:


Strict material selection: Use high-quality raw materials that meet industry standards.


Advanced technology: Use automated or precision-controlled production processes.


Multiple quality inspections: Implement full-process quality inspections from raw material storage to finished product delivery (including size, sealing, filtration efficiency, integrity testing, etc.).


Performance testing: Key products will undergo actual working condition simulation testing.


Compliance with standards: Our production and products comply with [e.g.: ISO 9001].


Customized verification: For customized filter elements, we will confirm key performance indicators with customers and provide test reports (if necessary).

Can metal cartridges be cleaned and reused, and how many cycles should I expect?

Yes . Reusability is usually the whole economic case, and it comes with two hard rules.


* Methods — Reverse-flow backflush at 1.5–2× service rate, ultrasonic cleaning in mild alkaline detergent, caustic or acid CIP, and calcination or steam for carbon and polymer residues.


* Never brush or scrape — That smears the pore structure and drives contamination deeper instead of out.


* Stay inside the chloride limit — 304 will pit at the weld in chloride-bearing water long before the media fails.


* Track the clean ΔP — Once it sits 30–50% above the original baseline, the pore structure is degrading rather than fouling — the cartridge is finished.

What is the difference between nominal and absolute micron ratings on metal media?

The two words are not interchangeable, and the gap between them is where process upsets come from.


- Nominal — Means 90–95% of particles above the stated size are retained, usually with no defined test method behind the claim.


- Absolute — Means 99.9% or better, verified by a defined method — bubble point to ISO 4003, glass-bead challenge, or a recognised particulate challenge.


- Ask which method — Metal ratings are normally derived from bubble-point pore size, so the method is the number.


- Why it matters — A mesh sold as 10 µm nominal will comfortably pass 25 µm particles. Irrelevant for a coarse strainer; fatal upstream of a spin pack or a membrane.

How do I specify a metal cartridge for polymer melt filtration?

Two numbers decide whether the cartridge survives: start-up ΔP, and collapse rating against the screen changer’s maximum.


* Process data — Polymer type (PET, PP, PA6, PE), melt temperature, viscosity at that temperature, throughput in kg/h, allowable pressure build-up.


* Hardware — Screen changer, spin pack or candle housing, with its pressure rating.


* Design on start-up, not steady state — Cold polymer can produce five to ten times the service differential pressure.


* No fibre release — Sintered powder or sintered mesh, not woven cloth, downstream of an extruder.

What do you need for a custom end connection, thread or flange?

Flange standards cause more rework than any other single item on a custom order.


* Dimensions : OD, ID, overall length, thread or flange specification and bolt circle. A drawing, or a photo with a caliper in frame, is enough.


* Connection and seal : M30×1, M36×2, BSP or NPT thread, ANSI or DIN flange, quick connector, bayonet — plus seal type and material.


* Duty : Media and rating, flow, allowable ΔP, temperature, pressure, quantity.

Which filter media should I use for my dust — polyester, anti-static, fiberglass, paper or non-woven?

Match the media to the dust chemistry and to how the collector cleans. Price is the last criterion.


- Polyester needle felt — to about 130 °C — General dry dust. The default choice, and the right starting point for most collectors.


- PTFE-laminated polyester — to about 130 °C — Fine or sticky fume, where dust must not key into the depth of the felt.


- Anti-static polyester, carbon or stainless fibre — to about 130 °C — Combustible dust, and any stream where charge build-up makes the cartridge hold dust it should have released.


- Fiberglass — to about 250 °C — High temperature, and any duty requiring H13 or H14 efficiency.


- Paper or cellulose — Coarse pre-filtration where cost dominates.


- Non-woven synthetic blends — Abrasive or moisture-laden streams.

Does a higher pleat count always mean better performance?

More pleats means more area — until the pleats crowd and cleaning can no longer reach the pleat root.


* What you gain — Lower face velocity, and therefore lower differential pressure at a given flow.


* What you lose — The gaps close under load, the cartridge blinds from the inside out, and the extra area is wasted.


* The metric that matters — Pleat pitch against dust loading: fine sticky dust wants wide spacing, free-flowing granular dust tolerates tight packing.


* Also check — Pleat depth against cage inside diameter. Deep pleats in a small cartridge fold over and create a dead zone that never cleans.

Why do my cartridges fail before their rated life, and how can I extend it?

Four modes account for most premature change-outs, and the fixes sit upstream of the cartridge.


* Media burst or abrasion — High inlet velocity, a missing deflector, or pulse pressure over about 6 bar at the venturi.


* Cage collapse — Differential pressure above rating, or water ingress.


* Adhesive or gasket failure — Temperature past the glue’s limit, or solvent attack.


* Rust-through — Galvanised cages in condensing streams.

What is the difference between a coalescer filter and a separator filter?

They are two distinct technologies often used together to remove liquids from a gas or liquid stream. The key difference is their core function:

* A Coalescer Filter merges tiny, invisible liquid droplets into large, heavy ones.

* A Separator Filter catches and drains those large droplets from the flow.

How They Work:

* Coalescer: The stream passes through a special media (like fine fibers). Microscopic aerosol droplets collide and merge (coalesce) into drops large enough to drain. It solves the problem of suspended mist.

* Separator: The flow then enters a chamber with baffles or vanes. The now-large droplets hit the surfaces, fall out by gravity, and collect in a sump. It provides the final, clean separation.

When do I need fiberglass or stainless instead of polyester, and how do I handle sparks?

Above roughly 130 °C continuous, polyester is out — and the gasket and cage need checking at the same time.

* Next step up — Fiberglass holds to about 260 °C; stainless or ceramic options go further.

* The weak link changes — Often the media survives and the glue line fails first, so the temperature rating must cover the whole assembly.

* Sparks — Welding, grinding, biomass boilers, foundry: a spark arrestor or pre-settling chamber upstream is mandatory. Fiberglass resists heat, not molten metal impingement.

* Condensing streams — Acid dew point corrodes cages faster than it destroys media, and a rusted cage collapses into the fan.
373-5471699
info@huahangfilter.com
+86 16690927259

    X