DMD0008D20B
Filter material
Paper
Filtration rate
1~50μm
End caps
Carbon steel
Working temperature
-20~+110℃
Origin
Henan,China
Share:
Products Description
Specification
Features

Products Description

This FILTREC DMD0008D20B replacement oil filter element, manufactured by our company, is a direct replacement filter that matches the specifications of the original FILTREC filter. Designed for hydraulic and lubrication systems, this filter provides reliable contaminant removal and system protection, ensuring your equipment operates at optimal efficiency and extends its lifespan. It’s a trustworthy and cost-effective option for maintenance professionals who need to ensure compatibility without compromising performance.

Choosing the correct replacement filter is crucial for system integrity. This filter’s dimensions and filtration characteristics are identical to the original DMD0008D20B part, providing a reliable solution and eliminating the risk of downtime caused by using incorrect or inferior filters.

Specification

Type Replace Oil Filter Element
Part number DMD0008D20B
End caps Carbon steel
Filter material Paper
Filtration rate 1~50μm
Working temperature -20~+110℃
Origin Henan, China
Package Neutral carton package

This is the specification of the standard DMD0008D20B replace oil filter element. If you need other part number, please contact us.

Features

Guaranteed FILTREC Compatibility & Perfect Seal: Manufactured to the precise dimensions and specifications of the original FILTREC DMD0008D20B filter. This ensures a perfect, leak-free fit in the designated housing, maintaining proper system flow and preventing unfiltered oil bypass.
Consistent Filtration Performance: Utilizes high-quality, depth-loading filtration media engineered to meet the original micron rating and dirt-holding capacity. It effectively captures wear particles, sludge, and other contaminants to maintain fluid cleanliness and protect pumps, valves, and actuators.
Robust Construction for Demanding Duty: Built with a durable inner core and reinforced end caps, this cartridge is designed to withstand system pressure surges and continuous operation. Its structural integrity prevents media migration or collapse, ensuring consistent protection throughout its service interval.
Integrated Safety & Sealing Reliability: Features precision-molded sealing gaskets for a positive seal. An accurately calibrated internal bypass valve (where applicable) provides critical system protection, ensuring oil flow under extreme conditions to prevent pump damage while signaling the need for service.
Didn't find your industry solution? Consult our technical experts immediately.

Related part number

Below is a list of some common alternative models. This is only a partial list; please send us your other requirements.

DHD240G05V DHD240G10B DHD240G10V DHD240G10V4 DHD240G20B DHD240G20V DHD240H03B
DHD240H05B DHD240H05V DHD240H10B DHD240H10V DHD240H20B DHD240H20V DHD240S100B
DHD240S200B DHD240S25B DHD240S50B DHD240S80B DHD280A03B DHD280A05B DHD280A10B
DHD280B100B DHD280B25B DHD280B50B DHD280G03B DHD280G03V DHD280G05B DHD280G05V
DHD280G10V DHD280G20B DHD280G20V DHD280H03B DHD30G03V DHD30G05B DHD30G05V
DHD30G10V DHD30G20B DHD30G20V DHD30H03B DHD30H03V DHD30H03V4 DHD30H05B
DHD30H10B DHD30H10V DHD30H20B DHD30H20V DHD30S100B DHD30S10B DHD30S150B
DHD30S25B DHD30S25V DHD30S40B DHD30S50B DHD30S80B DHD30T25B DHD30T40B
DHD30T80B DHD330A03B DHD330A05B DHD330A10B DHD330A20B DHD330B100B DHD330B150B

Manufacturer of Replace Oil Filter Element

Founded with a mission to deliver uncompromising reliability in fluid management, Huahang Filter has established itself as a leading manufacturer and solution provider in the industrial filtration sector. With years of dedicated expertise, we specialize in the design, engineering, and production of high-performance filtration products, most notably our advanced sintered mesh filters and comprehensive range of replacement filter elements.

Product Profile of Huahang Filter

Huahang serves a global clientele across vital sectors. Our portfolio spans:

  • Sintered Filters: For high-temperature gas filtration, polymer melt filtration, and critical fluid protection.
  • Replacement Filter Elements: Precision equivalents for major OEM brands (including Parker, Hydac, Pal and others), ensuring system compatibility without compromise.
  • Oil Filter Cartridges: A full spectrum of depth, particulate, and coalescing filters for lubrication, hydraulic, and fuel systems.

In addition to standard models, Huahang filter can also provide customized service according to customer needs, including dimensions, materials, end caps, and filter housings. Please contact us for specific information.

Related Products

Related Cases

Xinxiang City Huahang Filter Co., Ltd is professional in the production of Hydraulic Filter, Air Filter and Pipe Filter.Product series range from Oil Filter, Air Filter, Water Filter, Polymer Filter,Candle Filter Element, Stainless Steel Filter to filter Coalescer and Separator.

FAQ

How do I cross-reference my existing OEM part number to a Huahang element?

Send the OEM number plus one physical measurement. A part number alone is not enough to ship against.


* What we match on — Outside diameter, inside diameter, overall height, media grade, micron rating, end-cap and seal layout, bypass setting, collapse rating and flow direction.


* When the number is ambiguous — Superseded numbers, numbers shared across several machine builds, or an element that has clearly been substituted before. In those cases a photo of the housing nameplate and a caliper reading of the old element settle it.


* Why we insist — The most common return is not a wrong size. It is an element that fits the bore but seals on the wrong face.

What collapse or burst pressure can your elements take, and how does flow direction affect it?

Collapse rating comes from the core, not the media — and it only holds in service if two conditions are met.


* Typical ranges — A light return-line element with a perforated core around 10–25 bar; a pressure-line element with a heavy spiral core 100 bar and above; high-collapse designs higher still.


* Condition 1 — flow direction — Return elements are normally outside-in. Run one backwards and the pleat pack goes into tension, folds, and bypasses.


* Condition 2 — bypass setting — The housing’s bypass valve must crack below the element’s collapse rating. Otherwise a cold start or a neglected change-out crushes the element before the valve ever opens.

Can your elements handle fire-resistant fluids such as phosphate ester and EHC systems?

Yes, but the build changes, and this is exactly where a generic replacement fails.


* Seals — Move to FKM or PTFE. NBR swells and softens in phosphate ester.


* Media and bonds — Binder, pleat-seam adhesive and end-cap adhesive all have to resist ester attack; some phenolic resin systems do not.


* Water-based fluids (HFA, HFC) — A different problem again — free water, biological growth, and media that must not delaminate when wet.


* Expect a different ΔP — These fluids run at higher viscosity and lower lubricity than mineral oil, so the same element reads differently on the gauge.

What is the difference between an oil separator element and an oil mist separator?

Same job at different pressures: one works inside a compressor separator tank, the other on a breather or vacuum pump.


* Oil separator element — Removes oil aerosol from compressed air and returns the collected oil to the sump. Rated in mg/m³ carryover, typically a few mg/m³ for a healthy element.


* Oil mist separator — Comparable duty at near-atmospheric pressure, but sized on flow and oil type rather than on pressure.


* Saturation signals, common to both — Carryover climbing, oil consumption rising with no visible leak, ΔP trending up, and an element that comes out dark and varnished instead of evenly coated.

Sintered mesh, sintered powder or pleated stainless steel — how do I choose between them?

Choose on duty, not on price. The three constructions also fail in different ways.


* Sintered mesh : 2 to 5 diffusion-bonded wire layers — High strength, genuinely backflushable, cleanable surface, absolute ratings typically 3–100 µm. Best for catalyst recovery, amine and water service, and anything cleaned in place.


* Sintered powder : A true depth filter: narrow pore distribution, finer ratings (0.5–1 µm with titanium), more dirt capacity per unit area, better resistance to compressive load. The default for polymer melt, high-pressure gas and food or pharmaceutical duty where no fibre release is allowed.


* Pleated stainless : Woven wire cloth in a pleat pack — large area and low ΔP at high flow for coarse duty, and the lowest cost per square metre of area.

How do you ensure the quality and performance of the filter element?

Quality is our lifeline. We insist on:


Strict material selection: Use high-quality raw materials that meet industry standards.


Advanced technology: Use automated or precision-controlled production processes.


Multiple quality inspections: Implement full-process quality inspections from raw material storage to finished product delivery (including size, sealing, filtration efficiency, integrity testing, etc.).


Performance testing: Key products will undergo actual working condition simulation testing.


Compliance with standards: Our production and products comply with [e.g.: ISO 9001].


Customized verification: For customized filter elements, we will confirm key performance indicators with customers and provide test reports (if necessary).

Can metal cartridges be cleaned and reused, and how many cycles should I expect?

Yes . Reusability is usually the whole economic case, and it comes with two hard rules.


* Methods — Reverse-flow backflush at 1.5–2× service rate, ultrasonic cleaning in mild alkaline detergent, caustic or acid CIP, and calcination or steam for carbon and polymer residues.


* Never brush or scrape — That smears the pore structure and drives contamination deeper instead of out.


* Stay inside the chloride limit — 304 will pit at the weld in chloride-bearing water long before the media fails.


* Track the clean ΔP — Once it sits 30–50% above the original baseline, the pore structure is degrading rather than fouling — the cartridge is finished.

What is the difference between nominal and absolute micron ratings on metal media?

The two words are not interchangeable, and the gap between them is where process upsets come from.


- Nominal — Means 90–95% of particles above the stated size are retained, usually with no defined test method behind the claim.


- Absolute — Means 99.9% or better, verified by a defined method — bubble point to ISO 4003, glass-bead challenge, or a recognised particulate challenge.


- Ask which method — Metal ratings are normally derived from bubble-point pore size, so the method is the number.


- Why it matters — A mesh sold as 10 µm nominal will comfortably pass 25 µm particles. Irrelevant for a coarse strainer; fatal upstream of a spin pack or a membrane.

How do I specify a metal cartridge for polymer melt filtration?

Two numbers decide whether the cartridge survives: start-up ΔP, and collapse rating against the screen changer’s maximum.


* Process data — Polymer type (PET, PP, PA6, PE), melt temperature, viscosity at that temperature, throughput in kg/h, allowable pressure build-up.


* Hardware — Screen changer, spin pack or candle housing, with its pressure rating.


* Design on start-up, not steady state — Cold polymer can produce five to ten times the service differential pressure.


* No fibre release — Sintered powder or sintered mesh, not woven cloth, downstream of an extruder.

What do you need for a custom end connection, thread or flange?

Flange standards cause more rework than any other single item on a custom order.


* Dimensions : OD, ID, overall length, thread or flange specification and bolt circle. A drawing, or a photo with a caliper in frame, is enough.


* Connection and seal : M30×1, M36×2, BSP or NPT thread, ANSI or DIN flange, quick connector, bayonet — plus seal type and material.


* Duty : Media and rating, flow, allowable ΔP, temperature, pressure, quantity.

Which filter media should I use for my dust — polyester, anti-static, fiberglass, paper or non-woven?

Match the media to the dust chemistry and to how the collector cleans. Price is the last criterion.


- Polyester needle felt — to about 130 °C — General dry dust. The default choice, and the right starting point for most collectors.


- PTFE-laminated polyester — to about 130 °C — Fine or sticky fume, where dust must not key into the depth of the felt.


- Anti-static polyester, carbon or stainless fibre — to about 130 °C — Combustible dust, and any stream where charge build-up makes the cartridge hold dust it should have released.


- Fiberglass — to about 250 °C — High temperature, and any duty requiring H13 or H14 efficiency.


- Paper or cellulose — Coarse pre-filtration where cost dominates.


- Non-woven synthetic blends — Abrasive or moisture-laden streams.

Does a higher pleat count always mean better performance?

More pleats means more area — until the pleats crowd and cleaning can no longer reach the pleat root.


* What you gain — Lower face velocity, and therefore lower differential pressure at a given flow.


* What you lose — The gaps close under load, the cartridge blinds from the inside out, and the extra area is wasted.


* The metric that matters — Pleat pitch against dust loading: fine sticky dust wants wide spacing, free-flowing granular dust tolerates tight packing.


* Also check — Pleat depth against cage inside diameter. Deep pleats in a small cartridge fold over and create a dead zone that never cleans.

Why do my cartridges fail before their rated life, and how can I extend it?

Four modes account for most premature change-outs, and the fixes sit upstream of the cartridge.


* Media burst or abrasion — High inlet velocity, a missing deflector, or pulse pressure over about 6 bar at the venturi.


* Cage collapse — Differential pressure above rating, or water ingress.


* Adhesive or gasket failure — Temperature past the glue’s limit, or solvent attack.


* Rust-through — Galvanised cages in condensing streams.

What is the difference between a coalescer filter and a separator filter?

They are two distinct technologies often used together to remove liquids from a gas or liquid stream. The key difference is their core function:

* A Coalescer Filter merges tiny, invisible liquid droplets into large, heavy ones.

* A Separator Filter catches and drains those large droplets from the flow.

How They Work:

* Coalescer: The stream passes through a special media (like fine fibers). Microscopic aerosol droplets collide and merge (coalesce) into drops large enough to drain. It solves the problem of suspended mist.

* Separator: The flow then enters a chamber with baffles or vanes. The now-large droplets hit the surfaces, fall out by gravity, and collect in a sump. It provides the final, clean separation.

When do I need fiberglass or stainless instead of polyester, and how do I handle sparks?

Above roughly 130 °C continuous, polyester is out — and the gasket and cage need checking at the same time.

* Next step up — Fiberglass holds to about 260 °C; stainless or ceramic options go further.

* The weak link changes — Often the media survives and the glue line fails first, so the temperature rating must cover the whole assembly.

* Sparks — Welding, grinding, biomass boilers, foundry: a spark arrestor or pre-settling chamber upstream is mandatory. Fiberglass resists heat, not molten metal impingement.

* Condensing streams — Acid dew point corrodes cages faster than it destroys media, and a rusted cage collapses into the fan.
373-5471699
info@huahangfilter.com
+86 16690927259

    X